HP xp7030 User Guide - Page 49

Invalid parameter-command with current value

Page 49 highlights

The following table lists the types of notifications generated in various situations. This type of request... Modify a setting Query a setting Execute an action Generates this type of notification... Echoes the request command and shows the resulting value: Request: *BRT=65 Notification: *BRT=65 Echoes the request command and shows the resulting value: Request: *CON=? Notification: *CON=40 Echoes the request command: Request: *NXT Notification: *NXT Incorrect commands cause the following types of notifications: • No asterisk at start of command-no response • Unrecognized command name-command with "?" added • Command that is currently unavailable-command with "?" added • Invalid parameter-command with current value • Action command with unnecessary parameter-action command • Action command that is unavailable-action command The following simplified example shows how the projector typically responds to a request to change the active input source. Note that the three latter notifications are delayed. Request: Notification: *RSRC=4 *RSRC=4 *SRC=0 *SRC=4 *BRT=60 *CSPC=? (acknowledges request) (projector is attempting to acquire source 4, and in the interim has no valid source) (source 4 is now active) (brightness has been modified for source 4) (color space is not supported for this input) Connecting to a room controller 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Connecting to a room controller
49
The following table lists the types of notifications generated in various situations.
Incorrect commands cause the following types of notifications:
No asterisk at start of command—no response
Unrecognized command name—command with “?” added
Command that is currently unavailable—command with “?” added
Invalid parameter—command with current value
Action command with unnecessary parameter—action command
Action command that is unavailable—action command
The following simplified example shows how the projector typically responds to a request to
change the active input source. Note that the three latter notifications are delayed.
This type of request...
Generates this type of notification...
Modify a setting
Echoes the request command and shows the resulting value:
Request:
*BRT=65<CR>
Notification:
*BRT=65<CR><LF>
Query a setting
Echoes the request command and shows the resulting value:
Request:
*CON=?<CR>
Notification:
*CON=40<CR><LF>
Execute an action
Echoes the request command:
Request:
*NXT<CR>
Notification:
*NXT<CR><LF>
Request:
*RSRC=4<CR>
Notification:
*RSRC=4<CR><LF>
(acknowledges request)
*SRC=0<CR><LF>
(projector is attempting to acquire source 4, and in the interim
has no valid source)
*SRC=4<CR><LF>
(source 4 is now active)
*BRT=60<CR><LF>
(brightness has been modified for source 4)
*CSPC=?<CR><LF>
(color space is not supported for this input)