HP xp7030 User Guide - Page 49
Invalid parameter-command with current value
View all HP xp7030 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
The following table lists the types of notifications generated in various situations. This type of request... Modify a setting Query a setting Execute an action Generates this type of notification... Echoes the request command and shows the resulting value: Request: *BRT=65 Notification: *BRT=65 Echoes the request command and shows the resulting value: Request: *CON=? Notification: *CON=40 Echoes the request command: Request: *NXT Notification: *NXT Incorrect commands cause the following types of notifications: • No asterisk at start of command-no response • Unrecognized command name-command with "?" added • Command that is currently unavailable-command with "?" added • Invalid parameter-command with current value • Action command with unnecessary parameter-action command • Action command that is unavailable-action command The following simplified example shows how the projector typically responds to a request to change the active input source. Note that the three latter notifications are delayed. Request: Notification: *RSRC=4 *RSRC=4 *SRC=0 *SRC=4 *BRT=60 *CSPC=? (acknowledges request) (projector is attempting to acquire source 4, and in the interim has no valid source) (source 4 is now active) (brightness has been modified for source 4) (color space is not supported for this input) Connecting to a room controller 49