Hikvision DS-KH6320-WTE1 Configuration Guide - Page 33
Arming Mode Settings, Before You Start, → Shortcut, Alarm, Steps, → Scene, Stay Mode
View all Hikvision DS-KH6320-WTE1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Network Indoor Station Configuration Guide 2. Press a zone to pop up the zone editing dialogue box. 3. Set the zone type, alarm type, status of arming status, entering delay, and exiting delay. 4. Tap OK to save the settings. Note ● 7 zone types are selectable: Panic Button, Door Magnetic, Smoke Detector, Active Infrared, Passive Infrared, Gas Detector, and Doorbell. ● 3 alarm types are selectable: 24h Alarm, Instant Alarm, and Delay Alarm. Set the alarm type as 24h alarm, and the zone will be armed for 24h. Set the alarm type as instant alarm, and the zone will alarm once it's triggered. Set the alarm type as delay alarm, and you should set the entering delay duration and exiting delay duration. ● Both the entering delay duration and the exiting delay duration are from 30s to 60s. ● For Gas Detector, Smoke Detector and doorbell, the alarm type is set as default 24h alarm. The alarm type of them can not be changed. Arming Mode Settings 4 arming modes can be configured: stay mode, away mode, sleeping mode and custom mode. Before You Start Tap Settings → → Shortcut Settings to enable Alarm. Steps Note On the home page, the arming status function and zone settings function are hidden by default. You should enable the alarm function first. 1. Back to the home page, tap Settings → → Scene Settings to enter the arming mode settings page. 2. Tap Stay Mode, Away Mode, Sleeping Mode, or Custom to enter the page. 24