Hikvision DS-KH6320-WTE1 Configuration Guide - Page 62
Zone Alarm, Area No., Zone Type, Alarm Type, Entering Delay, Delay, IR Detector
View all Hikvision DS-KH6320-WTE1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Network Indoor Station Configuration Guide Figure 4-11 Zone Alarm 2. Select Area No. 3. Select Zone Type from the drop-down list. 4. Select Alarm Type from the drop-down list. 5. Set the NO/NC status. 6. Set Entering Delay and Exiting Delay. 7. Click Save to enable zone settings. Note ● 7 zone types are supported: Emergency Switch, Door Magnetic Switch, Smoke Detector, Active IR Detector, Passive IR Detector, Combustible Gas Detector, and DoorBell Switch. ● 3 types of alarm mode are supported: Instant Alarm, 24H Alarm, and Delay Alarm. ● When the zone type is set to be Instant Alarm, only under arming mode, the indoor station will receive alarm message when the detector is triggered. Under disarming mode, it will not receive alarm message when the detector is triggered. 53