Hitachi HTS541680J9AT00 Specifications - Page 119

Read Log Ext2Fh

Page 119 highlights

Travelstar 5K160 (PATA) Hard Disk Drive Specification 14.15 Read Log Ext(2Fh) Command Block Output Registers Register 76543210 Data Low -------- Data High -------- Feature Current Previous Sector Count Current V V V V V V V V Previous V V V V V V V V LBA Low Current V V V V V V V V Previous LBA Mid Current V V V V V V V V Previous V V V V V V V V LBA High Current Previous Device - - -D- - - - Command 00101111 Command Block Input Registers Register 76543210 Data Low -------- Data High -------- Error ...See Below... Sector Count HOB=0 HOB=1 LBA Low HOB=0 HOB=1 LBA Mid HOB=0 HOB=1 LBA High HOB=0 HOB=1 Device V Status ...See Below... Error Register 7 65432 1 0 CRC UNC 0 IDN 0 ABT T0N AMN V V0V0V 0 0 Figure 67 Read Log Ext command (2Fh) Status Register 7 654 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR 0 V0V - 0 - V This command returns the specified log to the host. The device shall interrupt for each DRQ block transferred. Output Parameters To The Device Sector Count Current The number of sectors to be read from the specified log low order, bits (7:0). The log transferred by the drive shall start at the sector in the specified log at the specified offset, regardless of the sector count requested. Sector Count Previous The number of sectors to be read from the specified log high orders, bits (15:8). LBA Low Current The log to be returned as described in Figure LBA Mid Current The first sector of the log to be read low order, bits (7:0). LBA Mid Previous The first sector of the log to be read high order, bits (15:8). Log address 00h 03h 07h 80h-9Fh Content Log directory Extended Comprehensive SMART error log Extended SMART self-test log Host vendor specific Figure 68 Log address definition Feature set N/A SMART error logging SMART self-test SMART Type Read Only Read Only Read Only Read/Wri te The Extended SMART self-test log sector shall support 48-bit and 28-bit addressing. All 28-bit entries contained in the SMART self-test log sector shall also be included in the Comprehensive SMART self-test log sector with the 48-bit entries. If the feature set associated with the log specified in the Sector Number register is not supported or enabled, or if the values in the Sector Count, Sector Number or Cylinder Low registers are invalid, the device shall return command aborted. 119/188

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

Travelstar 5K160 (PATA) Hard Disk Drive Specification
119
/
188
14.15
Read Log Ext(2Fh)
Command Block Output Registers
Command Block Input Registers
Register
7
6
5
4
3
2
1
0 Register
7
6
5
4
3
2
1
0
Data Low
-
-
-
-
-
-
-
-
Data Low
-
-
-
-
-
-
-
-
Data High
-
-
-
-
-
-
-
-
Data High
-
-
-
-
-
-
-
-
Current
-
-
-
-
-
-
-
-
Error
...See Below...
Feature
Previous
-
-
-
-
-
-
-
-
Current
V V V V
V
V
V
V
HOB=0
-
-
-
-
-
-
-
-
Sector Count
Previous
V V V V
V
V
V
V
Sector Count
HOB=1
-
-
-
-
-
-
-
-
Current
V V V V
V
V
V
V
HOB=0
-
-
-
-
-
-
-
-
LBA Low
Previous
-
-
-
-
-
-
-
-
LBA Low
HOB=1
-
-
-
-
-
-
-
-
Current
V V V V
V
V
V
V
HOB=0
-
-
-
-
-
-
-
-
LBA Mid
Previous
V V V V
V
V
V
V
LBA Mid
HOB=1
-
-
-
-
-
-
-
-
Current
-
-
-
-
-
-
-
-
HOB=0
-
-
-
-
-
-
-
-
LBA High
Previous
-
-
-
-
-
-
-
-
LBA High
HOB=1
-
-
-
-
-
-
-
-
Device
-
-
-
D
-
-
-
-
Device
V
-
-
-
-
-
-
-
Command
0
0
1
0
1
1
1
1 Status
...See Below...
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY
RDY
DF
DSC
DRQ COR
IDX
ERR
V
V
0
V
0
V
0
0
0
V
0
V
-
0
-
V
Figure 67 Read Log Ext command (2Fh)
This command returns the specified log to the host. The device shall interrupt for each DRQ block transferred.
Output Parameters To The Device
Sector Count Current
The number of sectors to be read from the specified log low order, bits (7:0). The log
transferred by the drive shall start at the sector in the specified log at the specified
offset, regardless of the sector count requested.
Sector Count Previous
The number of sectors to be read from the specified log high orders, bits (15:8).
LBA Low Current
The log to be returned as described in Figure
LBA Mid Current
The first sector of the log to be read low order, bits (7:0).
LBA Mid Previous
The first sector of the log to be read high order, bits (15:8).
Log
address
Content
Feature set
Type
00h
Log directory
N/A
Read Only
03h
Extended Comprehensive SMART
error log
SMART
error
logging
Read Only
07h
Extended SMART self-test log
SMART self-test
Read Only
80h-9Fh
Host vendor specific
SMART
Read/Wri
te
Figure 68 Log address definition
The Extended SMART self-test log sector shall support 48-bit and 28-bit addressing. All 28-bit entries contained in
the SMART self-test log sector shall also be included in the Comprehensive SMART self-test log sector with the
48-bit entries.
If the feature set associated with the log specified in the Sector Number register is not supported or enabled, or if the
values in the Sector Count, Sector Number or Cylinder Low registers are invalid, the device shall return command
aborted.