Husqvarna AUTOMOWER SOLAR HYBRID Operation Manual - Page 59

Garden Example

Page 59 highlights

7. GARDEN EXAMPLE Proposals for installation and settings Area: 1,800 m2. No guide wire is necessary. Timer: Operating time of 20 hours per day. Exit angles: 90° - 270°. Search method: Irregular and Follow boundary wire in. Delay: Guide 1 4 minutes, Guide 2 4 minutes and boundary wire 11 minutes. Corridor width: Boundary wire 20 Area: 1,800 m2. A number of islands and a steep slope along the boundary wire. Guide wire recommended. Timer: Operating time of 20 hours per day. Exit angles: 90°-270°. Search method: Irregular and Follow guide wire in. Delay: Guide 1 4 minutes, Guide 2 4 minutes and boundary wire 99 minutes. Automower® is never permitted to follow the boundary wire. Corridor width: Guide 1 20, Guide 2 20. Area: 600 m2. L-shaped garden with the charging station placed in the large open area. No guide wire is necessary. Timer: Operating time of 7 hours per day. Exit angles: 90° - 270°. Search method: Irregular and Follow boundary wire in. Delay: Guide 1 4 minutes, Guide 2 4 minutes and boundary wire 11 minutes. Corridor width: Boundary wire 20 60 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

60 - English
7. GARDEN EXAMPLE
Area: 1,800 m
2
. No guide wire is necessary.
Timer
: Operating time of 20 hours per day.
Exit angles
: 90° - 270°.
Search method: Irregular and Follow
boundary wire in.
Delay: Guide 1 4 minutes, Guide 2 4 minutes
and boundary wire 11 minutes.
Corridor width
:
Boundary wire 20
Area: 1,800 m
2
. A number of islands and a
steep slope along the boundary wire. Guide
wire recommended.
Timer
: Operating time of 20 hours per day.
Exit angles
: 90°-270°.
Search method: Irregular and Follow guide
wire in.
Delay:
Guide 1 4 minutes, Guide 2 4 minutes
and boundary wire 99 minutes. Automower
®
is never permitted to follow the boundary
wire.
Corridor width
:
Guide 1 20, Guide 2 20.
Area: 600 m
2
. L-shaped garden with the
charging station placed in the large open
area. No guide wire is necessary.
Timer
: Operating time of 7 hours per day.
Exit angles
: 90°
- 270°.
Search method: Irregular and Follow
boundary wire in.
Delay: Guide 1 4 minutes, Guide 2 4 minutes
and boundary wire 11 minutes.
Corridor width
:
Boundary wire 20
Proposals for installation and settings