Husqvarna AUTOMOWER SOLAR HYBRID Operation Manual - Page 60

Timer, Exit angles, Follow loop out, Corridor width

Page 60 highlights

7. GARDEN EXAMPLE Proposals for installation and settings Area: 600 m2. L-shaped garden with the charging station placed in the narrow area. There are two islands. No guide wire is necessary. Timer: Operating time of 7 hours per day. Exit angles: 250° - 290°. Search method: Irregular and Follow boundary wire in. Delay: Guide 1 4 minutes, Guide 2 4 minutes and boundary wire 11 minutes. Corridor width: 10 Area: 700 m2. U-shaped garden with the charging station placed on one of the large open areas. Guide wire recommended through the passage. Timer: Operating time of 8 hours per day. Exit angles: 90° - 270°. Follow loop out: Direction Guide 1, Distance 25 metres and Proportion 30 %. Search method: Irregular and Follow guide wire in. Delay: Guide 1 3 minutes, Guide 2 4 minutes and boundary wire 99 minutes. Automower® is never permitted to follow the boundary wire. Corridor width: Guide 1 3 Area: 800 m2. Rectangular garden with the charging station placed by an island. A large part of the boundary wire is routed on a slope that is steeper than 10 %. Guide wire recommended. Timer: Operating time of 9 hours per day. Exit angles: 90° - 270°. Search method: Irregular and Follow guide wire in. Delay: Guide 1 4 minutes, Guide 2 4 minutes and boundary wire 99 minutes. Automower® is never permitted to follow the boundary wire. Corridor width: Guide 1 20 English - 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

English - 61
7. GARDEN EXAMPLE
Area: 600 m
2
. L-shaped garden with the
charging station placed in the narrow area.
There are two islands. No guide wire is
necessary.
Timer
: Operating time of 7 hours per day.
Exit angles
:
250° - 290°.
Search method: Irregular and Follow
boundary wire in.
Delay: Guide 1 4 minutes, Guide 2 4 minutes
and boundary wire 11 minutes.
Corridor width
: 10
Area: 700 m
2
. U-shaped garden with the
charging station placed on one of the large
open areas. Guide wire recommended
through the passage.
Timer
: Operating time of 8 hours per day.
Exit angles: 90° - 270°.
Follow loop out:
Direction
Guide 1
,
Distance
25 metres and
Proportion
30 %.
Search method: Irregular and Follow guide
wire in.
Delay:
Guide 1 3 minutes, Guide 2 4 minutes
and boundary wire 99 minutes. Automower
®
is never permitted to follow the boundary
wire.
Corridor width:
Guide 1 3
Area: 800 m
2
. Rectangular garden with the
charging station placed by an island. A large
part of the boundary wire is routed on a slope
that is steeper than 10 %. Guide wire
recommended.
Timer
: Operating time of 9 hours per day.
Exit angles
: 90° - 270°.
Search method: Irregular and Follow guide
wire in.
Delay:
Guide 1 4 minutes, Guide 2 4 minutes
and boundary wire 99 minutes. Automower
®
is never permitted to follow the boundary
wire.
Corridor width:
Guide 1 20