Icom IC-2730A Instruction Manual - Page 49

■ Setting and clearing skipchannels, ■ Setting the temporary skipfunction

Page 49 highlights

SCAN OPERATION 5 ■■Setting and clearing skip channels The channels that are set as "SKIP" or "PSKIP" channels are skipped (not scanned). qqPush [MR CALL]S. • Selects the Memory mode. wwRotate [DIAL]S to select a memory channel to be set. eeHold down [MW]C for 1 second to display the Memory edit screen. rrPush [ï]D. ttRotate [DIAL]S to select "SKIP." yyPush [ï]D. uuRotate [DIAL]S to select a desired option. • OFF: Cancel the skip setting. • SKIP: Skipped during a memory scan. • PSKIP: Skipped during both VFO and memory scans. iiRotate [DIAL]S to select "WRITE." • Displays "OVERW?." ooRotate [DIAL]S to select "YES." !0 Push [ï]D. • Beeps sound, and sets the skip setting. • "SKIP" appears. • W hen you select "OFF" in step u, no icon appears. ■■Setting the temporary skip function This function temporarily skips up to five unwanted frequen- cies during a scan, for the set time period, without setting the skip frequency. This function can be used only when the HM-207 (supplied), HM-154 (optional) microphone or VS-3 Bluetooth® headset is connected. qqStart a VFO scan. (p. 41) • When a signal is received, the scan pauses. 5 wwWhile the scan is pausing, push the key that the "T-SKIP" (Temporary Skip) function is assigned to. • The Temporary skip function is set. eeAfter setting the temporary skip function, the scan resumes. • After the Temporary Skip time period passes, or the scan is can- celled, the Temporary Skip is also cancelled. For your reference: • Up to five Temporary Skip frequencies or memories can be set. • During a Memory scan, follow steps w and e to skip the channel for the set time period (Default: 5 minutes). • T he Temporary Skip time period is set to "5 minutes" by default. You can change the setting in the "TEMP" (Temporary Skip Timer) item of EXMENU mode. (p. 13) SCAN OPERATION 44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

44
5
SCAN OPERATION
5
SCAN OPERATION
Setting and clearing skip
channels
The channels that are set as “SKIP” or “PSKIP” channels are
skipped (not scanned).
Push [MR CALL]
q
S
.
• Selects the Memory mode.
Rotate [DIAL]
w
S
to select a memory channel to be set.
Hold down [MW]
e
C
for 1 second to display the Memory
edit screen.
Push [
r
ï
]
D
.
Rotate [DIAL]
t
S
to select “SKIP.”
Push [
y
ï
]
D
.
Rotate [DIAL]
u
S
to select a desired option.
• OFF:
Cancel the skip setting.
• SKIP:
Skipped during a memory scan.
• PSKIP: Skipped during both VFO and memory scans.
Rotate [DIAL]
i
S
to select “WRITE.”
• Displays “OVERW?.”
Rotate [DIAL]
o
S
to select “YES.”
!
0
Push [
ï
]
D
.
• Beeps sound, and sets the skip setting.
• “SKIP” appears.
• When you select “OFF” in step
u
, no icon appears.
Setting the temporary skip
function
This function temporarily skips up to five unwanted frequen-
cies during a scan, for the set time period, without setting the
skip frequency.
This function can be used only when the HM-207 (supplied),
HM-154 (optional) microphone or VS-3
Bluetooth
®
HEADSET
is
connected.
Start a VFO scan. (p. 41)
q
• When a signal is received, the scan pauses.
While the scan is pausing, push the key that the “T-SKIP”
w
(Temporary Skip) function is assigned to.
• The Temporary skip function is set.
After setting the temporary skip function, the scan resumes.
e
• After the Temporary Skip time period passes, or the scan is can
-
celled, the Temporary Skip is also cancelled.
For your reference:
• Up to five Temporary Skip frequencies or memories can
be set.
• During a Memory scan, follow steps
w
and
e
to skip the
channel for the set time period (Default: 5 minutes).
• The Temporary Skip
time period is set to “5 minutes” by
default. You can change the setting in the “TEMP” (Tempo-
rary Skip Timer) item of EXMENU mode.
(p. 13)