Icom MR-1220 Instruction Manual - Page 54

Installing the scanner unit (Open array types

Page 54 highlights

9 Installation and connections IInnsstatlalinlglitnhge stchanenesrcuannit (nOeprenuanrriaty(tOyppese)n array types) For the SC-T40, SC-T60, and SC-T60L open array type scanner units. DDMounting the scanner unit RRWARNING! TURN OFF the display unit whenever you are working with the scanner unit. 1. Using the Open array scanner unit template that is supplied with the scanner unit, drill 4 holes 12 mm (0.47 inch) in diameter, where you want to mount the scanner unit. 2. If the mounting surface or platform is metal, apply a sealing compound around the holes to prevent corrosion and water ingress. 3. Mount the scanner unit in place using the supplied bolts (M10 × 40 mm), flat washers, and spring washers. LLSecure the bolts firmly. Ship's bow 190 (7.48) 400 (15.75) 262 (10.31) R5.5 (0.22) 11 (0.43) 20.5 (0.81) 395 (15.55) 190 (7.48) 200 (7.87) 116.5 (4.59) SC-40T/SC-60T: 1192 (46.93), SC-60TL:1979 (77.91) 370 (14.57) Ship's bow 248 (9.76) 302 (11.89) Unit: mm (inch) 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

49
9
INSTALLATION AND CONNECTIONS
Installing the scanner unit (Open array types)
Installing the scanner unit (Open array types)
For the SC-T40, SC-T60, and SC-T60L open array type scanner units.
D
Mounting the scanner unit
R
WARNING! TURN OFF
the display unit
whenever you are working with the scanner
unit.
1.
Using the Open array scanner unit template that is
supplied with the scanner unit, drill 4 holes 12 mm
(0.47 inch) in diameter, where you want to mount
the scanner unit.
2.
If the mounting surface or platform is metal, apply
a sealing compound around the holes to prevent
corrosion and water ingress.
3.
Mount the scanner unit in place using the supplied
bolts (M10 × 40 mm), flat washers, and spring
washers.
L
Secure the bolts firmly.
R5.5 (0.22)
20.5 (0.81)
11 (0.43)
262 (10.31)
302 (11.89)
248 (9.76)
370 (14.57)
190 (7.48)
200 (7.87)
116.5 (4.59)
SC-40T/SC-60T: 1192 (46.93), SC-60TL:1979 (77.91)
190 (7.48)
400 (15.75)
395 (15.55)
Ship’s bow
Ship’s bow
Unit: mm (inch)