Intel D865GLC Manual - Page 50

Error and Information Messages - bios updates

Page 50 highlights

Error and Information Messages The rest of this chapter describes beep codes, and error messages that you might see or hear when you start up the system: BIOS Error Messages Table 15: BIOS Error Messages Error Message Explanation GA20 Error An error occurred with Gate A20 when switching to protected mode during the memory test. Pri Master HDD Error Could not read sector from corresponding drive. Pri Slave HDD Error Sec Master HDD Error Sec Slave HDD Error Pri Master Drive - ATAPI Incompatible Corresponding drive in not an ATAPI device. Run Setup to make sure device is selected correctly. Pri Slave Drive - ATAPI Incompatible Sec Master Drive - ATAPI Incompatible Sec Slave Drive - ATAPI Incompatible A: Drive Error No response from diskette drive. Cache Memory Bad An error occurred when testing L2 cache. Cache memory may be bad. CMOS Battery Low The battery may be losing power. Replace the battery soon. CMOS Display Type Wrong The display type is different than what has been stored in CMOS. Check Setup to make sure type is correct. CMOS Checksum Bad The CMOS checksum is incorrect. CMOS memory may have been corrupted. Run Setup to reset values. CMOS Settings Wrong CMOS values are not the same as the last boot. These values have either been corrupted or the battery has failed. CMOS Date/Time Not Set The time and/or date values stored in CMOS are invalid. Run Setup to set correct values. DMA Error Error during read/write test of DMA controller. FDC Failure Error occurred trying to access diskette drive controller. HDC Failure Error occurred trying to access hard disk controller. Checking NVRAM..... NVRAM is being checked to see if it is valid. Update OK! NVRAM was invalid and has been updated. Updated Failed NVRAM was invalid but was unable to be updated. Keyboard Error Error in the keyboard connection. Make sure keyboard is connected properly. KB/Interface Error Keyboard interface test failed. Memory Size Decreased Memory size has decreased since the last boot. If no memory was removed then memory may be bad. Memory Size Increased Memory size has increased since the last boot. If no memory was added there may be a problem with the system. D865GLC Motherboard Manual 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109

D865GLC Motherboard Manual
49
Error and Information Messages
The rest of this chapter describes beep codes, and error messages that you might
see or hear when you start up the system:
BIOS Error Messages
Table 15:
BIOS Error Messages
Error Message
Explanation
GA20 Error
An error occurred with Gate A20 when switching to protected
mode
during the memory test.
Pri Master HDD Error
Pri Slave HDD Error
Sec Master HDD Error
Sec Slave HDD Error
Could not read sector from corresponding drive.
Pri Master Drive - ATAPI
Incompatible
Pri Slave Drive - ATAPI
Incompatible
Sec Master Drive - ATAPI
Incompatible
Sec Slave Drive - ATAPI
Incompatible
Corresponding drive in not an ATAPI device. Run Setup to make sure
device is selected correctly.
A: Drive Error
No response from diskette drive.
Cache Memory Bad
An error occurred when testing L2 cache. Cache memory may be
bad.
CMOS Battery Low
The battery may be losing power. Replace the battery soon.
CMOS Display Type Wrong
The display type is different than what has been stored in CMOS.
Check Setup to make sure type is correct.
CMOS Checksum Bad
The CMOS checksum is incorrect. CMOS memory may have
been
corrupted. Run Setup to reset values.
CMOS Settings Wrong
CMOS values are not the same as the last boot. These values
have
either been corrupted or the battery has failed.
CMOS Date/Time Not Set
The time and/or date values stored in CMOS are invalid. Run
Setup to set correct values.
DMA Error
Error during read/write test of DMA controller.
FDC Failure
Error occurred trying to access diskette drive controller.
HDC Failure
Error occurred trying to access hard disk controller.
Checking NVRAM
.....
NVRAM is being checked to see if it is valid.
Update OK!
NVRAM was invalid and has been updated.
Updated Failed
NVRAM was invalid but was unable to be updated.
Keyboard Error
Error in the keyboard connection. Make sure keyboard is
connected
properly.
KB/Interface Error
Keyboard interface test failed.
Memory Size Decreased
Memory size has decreased since the last boot. If no memory
was
removed then memory may be bad.
Memory Size Increased
Memory size has increased since the last boot. If no memory was
added there may be a problem with the system.