Intel S1200RP Technical Product Specification - Page 211
BMC Force Update Jumper Block
View all Intel S1200RP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 211 highlights
Intel® Server Board S1200V3RP Jumper Blocks 11. Install AC power cords. 12. Power on system. 10.5 BMC Force Update Jumper Block The BMC Force Update jumper is used to put the BMC in Boot Recovery mode for a low-level update. It is used when the BMC has become corrupted and is non-functional, requiring a new BMC image to be loaded on to the server board. 1. Turn off the system and remove power cords. 2. Move the BMC FRC UPDT Jumper from the default (pins 1 and 2) operating position to the Force Update position (pins 2 and 3). 3. Re-attach system power cords. 4. Power on the system. Note: System Fans will boost and the BIOS Error Manager should report an 84F3 error code (Baseboard Management Controller in update mode). 5. Boot to the EFI shell and update the BMC firmware using BMC####.NSH (where #### is the version number of the BMC). 6. When update has successfully completed, power off system. 7. Remove AC power cords. 8. Move BMC FRC UPDT jumper back to the default position. 9. Install AC power cords. 10. Power on system. 11. Boot to the EFI shell and update the FRU and SDR data using FRUSDR####.nsh (where #### is the version number of the FRUSDR package). 12. Reboot the system. 13. Configure desired BMC configuration settings. Revision 1.0 199