JVC DLA-RS45U Command Communication Specification for D-ILA Projectors (v1.7 f - Page 69

Service setup [Service Setup]

Page 69 highlights

4 Command control 4.15 Service setup [Service Setup] Used to change the service setting. Command code HEX 0x53 0x53 ASCII 'S' 'S' Table 4-92 SERVICE SETUP CMD Function Service setting [Service Setup] Parameter1 Data length: No regulation Sub command table (Mandatory command only) Table 4-93 SERVICE SETUP CMD SUB HEX 0x4C 0x54 0x4C 0x53 0x53 0x54 0x54 0x46 0x46 0x46 0x49 0x45 0x53 0x4C 0x53 0x4D 0x4D 0x4D 0x50 0x52 0x47 0x42 0x54 0x54 0x56 0x44 0x4E 0x52 0x47 0x42 ASCII 'L' 'T' 'L' 'S' 'S' 'T' 'T' 'P' 'F' 'R' 'F' 'G' 'F' 'B' 'I' 'T' 'E' 'T' 'S' 'V' 'L' 'D' 'S' 'N' 'M' 'R' 'M' 'G' 'M' 'B' Function Lamp time reset/reference (Reset is available only at Standby mode) Lamp accumulated time reset/reference (Reset is available only at Standby mode) System Time reset/reference (Reset is available only at Standby mode) Test Pattern for adjustment Flat Pattern level (Red) adjustment Flat Pattern level (Green) adjustment Flat Pattern level (Blue) adjustment Internal Temperature reference Outside Temperature reference Adjustment Data save Adjustment Data load Serial Number Mute (Red)(*1) Mute (Green) (*1) Mute (Blue) (*1) Data Last type memory Special1 No Special1 No Special1 No Special2 No Numeric Yes Numeric Yes Numeric Yes Numeric No Numeric No Special3 No Special3 No Special4 Yes Special5 Yes Special5 Yes Special5 Yes It consists of "Sub command" + "Setting". Sub command consists of ASCII character 2 bytes. Operation - Reference - (*1) Do not change muting status other than specified color. For example, keep the red mute On if you set the green mute to On when the red mute is On. Parameter2 Parameter2 is data depending on Sub command. Data length: Depending on Sub command as follow. Data type Numeric Special1 Special2 Data length 4 bytes 1 byte (Reset)/6 bytes (Reference) 2 bytes Special3 256 bytes Special4 Special5 18 bytes 1 byte Note ASCII Character ASCII Character ASCII Character Binary Data Current Adjustment Data (except Gamma) ASCII Character (Same as "Calibrator Information") ASCII Character 69 / 80 PJ03220107B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

4 Command control
69 / 80
PJ03220107B
4.15 Service setup [Service Setup]
Used to change the service setting.
Command code
Table 4-92
SERVICE SETUP CMD
HEX
ASCII
Function
0x53
0x53
'S'
'S'
Service setting [Service Setup]
Parameter1
Data length:
No regulation
Sub command table (Mandatory command only)
Table 4-93
SERVICE SETUP CMD SUB
HEX
ASCII
Function
Data
type
Last
memory
Operation
Reference
0x4C
0x54
‘L’
‘T’
Lamp time reset/reference
(Reset is available only at Standby mode)
Special1
No
°
°
0x4C
0x53
‘L’
‘S’
Lamp accumulated time reset/reference
(Reset is available only at Standby mode)
Special1
No
°
°
0x53
0x54
‘S’
‘T’
System Time reset/reference
(Reset is available only at Standby mode)
Special1
No
°
°
0x54
0x50
'T'
‘P'
Test Pattern for adjustment
Special2
No
°
°
0x46
0x52
‘F’
‘R'
Flat Pattern level (Red) adjustment
Numeric
Yes
°
°
0x46
0x47
‘F’
‘G'
Flat Pattern level (Green) adjustment
Numeric
Yes
°
°
0x46
0x42
‘F’
‘B'
Flat Pattern level (Blue) adjustment
Numeric
Yes
°
°
0x49
0x54
‘I’
‘T’
Internal Temperature reference
Numeric
No
-
°
0x45
0x54
‘E’
‘T’
Outside Temperature reference
Numeric
No
-
°
0x53
0x56
‘S’
‘V’
Adjustment Data save
Special3
No
-
°
0x4C
0x44
‘L’
‘D’
Adjustment Data load
Special3
No
°
-
0x53
0x4E
‘S’
‘N’
Serial Number
Special4
Yes
°
°
0x4D
0x52
‘M’
‘R'
Mute (Red)(*1
Special5
Yes
°
°
0x4D
0x47
‘M’
‘G'
Mute (Green) (*1)
Special5
Yes
°
°
0x4D
0x42
‘M’
‘B'
Mute (Blue) (*1)
Special5
Yes
°
°
°
It consists of “Sub command” + “Setting”. Sub command consists of ASCII character 2 bytes.
(*1) Do not change muting status other than specified color.
For example, keep the red mute On if you set the green mute to On when the red mute is On.
Parameter2
Parameter2 is data depending on Sub command.
Data length:
Depending on Sub command as follow.
Data type
Data length
Note
Numeric
4 bytes
ASCII Character
Special1
1 byte (Reset)/6 bytes (Reference)
ASCII Character
Special2
2 bytes
ASCII Character
Special3
256 bytes
Binary Data
Current Adjustment Data (except Gamma)
Special4
18 bytes
ASCII Character
(Same as “Calibrator Information”)
Special5
1 byte
ASCII Character