JVC DLA-RS45U Command Communication Specification for D-ILA Projectors (v1.7 f - Page 77

Purpose: To confirm the internal temperature., Purpose: To confirm the lamp accumulated time.

Page 77 highlights

4 Command control 4.15.2 Reference Use the command as shown in the following examples. (Example1) Internal temperature confirmation Purpose: To confirm the internal temperature. (1) Transmit the data from the external controller to the projector as follows. 1: External controller → 0x3F 0x89 0x01 0x53 '?'(Reference) PJ Individual : 1 'S' 0x53 'S' 0x49 'I' 0x54 'T' 0x0A End (2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows. 2: ← Projector 0x06 0x89 0x01 0x53 0x53 0x0A ACK PJ Individual : 1 'S' 'S' End (3) The projector transmits the internal temperature of 30 to the external controller. 3: ← Projector 0x40 0x89 0x01 0x53 0x53 '@'(Response) PJ Individual : 1 'S' 'S' 0x46 '0' 0x46 '0' 0x31 '1' 0x45 'E' 0x0A End By the above exchange, it can be confirmed that the internal temperature is 30℃. (Example2) Lamp accumulated time confirmation Purpose: To confirm the lamp accumulated time. (1) Transmit the data from the external controller to the projector as follows. 1: External controller → 0x3F 0x89 0x01 0x53 '?'(Reference) PJ Individual : 1 'S' 0x53 'S' 0x4C 'L' 0x53 'S' 0x0A End (2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows. 2: ← Projector 0x06 0x89 0x01 0x53 0x53 0x0A ACK PJ Individual : 1 'S' 'S' End (3) The projector transmits the lamp accumulated time of 10,000 hours (=600,000 minutes) to the external controller. 3: ← Projector 0x40 0x89 0x01 0x53 0x53 0x30 0x39 0x32 0x37 0x43 '@'(Response) PJ Individual : 1 'S' 'S' 600,000 minutes (=0x0927C0) 0x30 0x0A End By the above exchange, it can be confirmed that the lamp accumulated time is 10,000 hours. 77 / 80 PJ03220107B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

4 Command control
77 / 80
PJ03220107B
4.15.2 Reference
Use the command as shown in the following examples.
(Example1) Internal temperature confirmation
Purpose: To confirm the internal temperature.
(1) Transmit the data from the external controller to the projector as follows.
1: External controller
0x3F
0x89
0x01
0x53
0x53
0x49
0x54
0x0A
'?'(Reference)
PJ
Individual : 1
'S'
'S'
‘I’
‘T’
End
(2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows.
2:
Projector
0x06
0x89
0x01
0x53
0x53
0x0A
ACK
PJ
Individual : 1
'S'
'S'
End
(3) The projector transmits the internal temperature of 30
to the
external controller.
3:
Projector
0x40
0x89
0x01
0x53
0x53
0x46
0x46
0x31
0x45
0x0A
'@'(Response)
PJ
Individual : 1
'S'
'S'
‘0’
‘0’
‘1’
‘E’
End
By the above exchange, it can be confirmed that the internal temperature is 30
.
(Example2) Lamp accumulated time confirmation
Purpose: To confirm the lamp accumulated time.
(1) Transmit the data from the external controller to the projector as follows.
1: External controller
0x3F
0x89
0x01
0x53
0x53
0x4C
0x53
0x0A
'?'(Reference)
PJ
Individual : 1
'S'
'S'
‘L’
‘S’
End
(2) If the projector receives the data (1) above and the command receipt is normal, an ACK is returned from the projector as follows.
2:
Projector
0x06
0x89
0x01
0x53
0x53
0x0A
ACK
PJ
Individual : 1
'S'
'S'
End
(3) The projector transmits the lamp accumulated time of 10,000 hours (=600,000 minutes) to the external controller.
3:
Projector
0x40
0x89
0x01
0x53
0x53
0x30
0x39
0x32
0x37
0x43
0x30
0x0A
'@'(Response)
PJ
Individual : 1
'S'
'S'
600,000 minutes (=0x0927C0)
End
By the above exchange, it can be confirmed that the lamp accumulated time is 10,000 hours.