Invalid IA level, Interlocks are open - firmware
UPC - 041778263082
View all Kodak I840 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
Message Message Action Message Action Message Action Message Action Message Action Message Action Message Action Message Action Message Action Message Action Message Action Message Action Description Feeder self test failed The self-test of the paper feeder failed. Perform a controlled power-down sequence on the scanner. If the problem persists, call Service. Front image cal unsuccessful The imaging calibration for the front camera was unsuccessful. Clean the imaging guides and retry calibration. See Chapter 5, Maintenance, "Cleaning the imaging guides" for cleaning procedures. Image address field overflow One of the image address fields has exceeded its maximum configured count. Check to make sure that a level change was not missed or reconfigure the scanner to allow a larger value for the overflowed field. Image buffer almost full The feeder has stopped and the transport is still running because the image buffer is almost full. Processing will resume when the buffer is less full. Image buffer full The image buffer overflowed. One or more documents that passed through the transport were not scanned. Refeed all documents for which images were not obtained. Images in buffer You tried to enable the scanner when images were still in the buffer. Not all images were retrieved. Retrieve the remaining images or clear the buffer. When the buffer is cleared, you may enable the scanner. Interlocks are closed Informational message. All doors are closed. Interlocks are open One of the doors is not closed or an error has not been cleared since the door(s) was last opened. Check to see that all doors are closed and clear the error by pressing the Return arrow (left button) on the Control Panel. Invalid IA level The image address level you tried to enter is not valid. Re-enter a correct image address level. For more information about image addressing, see Kodak publication, Kodak i800 Series Scanners, Image Processing Guide, A-61510. IPB needs firmware There is no firmware in an image processing board. Firmware needs to be installed in all image processing boards before scanning is possible. Call Service. Lamps not ready Calibration and/or scanning was attempted before the lamps were warmed up. See Chapter 3, Operator Control Panel Function's for calibration guidelines and procedures. Lamps ready for scanning Although lamps have warmed up sufficiently to allow scanning, image quality will be best after the lamps have stabilized after approximately 10 minutes. A-61169 July 2003 6-7