Konica Minolta MGI iFOIL S Printing Press iFOILs User Manual - Page 58

MACHINE ERROR CODE AND TROUBLESHOOTING, Machine error code

Page 58 highlights

iFOIL S 7.Machine error code and troubleshooting 7. MACHINE ERROR CODE AND TROUBLESHOOTING 7.1 Machine error code Code Description 1 Error Sercos bus module 21K2 PS 2 Error Sercos bus module 21K3 AI 3 Error Sercos bus module 29K1 AO 4 Error Sercos bus module 22K1 AO 5 Error Sercos bus module 22K2 In 6 Error Sercos bus module 23K1 In 7 Error Sercos bus module 24K1 In 8 Error Sercos bus module 26K1 Out 9 Error Sercos bus module 26K2 PS 10 Error Sercos bus module 27K1 Out 11 Error Sercos bus module 28K1 Out 12 Mot. prot. fuse released 13 Fuse IO released 14 Fuse fan belt released 15 Fuse fan door released 16 Emergency stop 17 Safety door open 18 No air pressure 20 Gap adjustment error Cause Error at Sercos bus terminal, Power supply, terminal 21K2 Solution Note error warning Call service Error at Sercos bus terminal, Analog input, terminal 21K3 Note error warning Call service Error at Sercos bus terminal, Analog output, terminal 29K1 Note error warning Call service Error at Sercos bus terminal, Analog output, terminal 22K1 Note error warning Call service Error at Sercos bus terminal, Input, Note error warning terminal 22K2 Call service Error at Sercos bus terminal, Input, Note error warning terminal 23K1 Call service Error at Sercos bus terminal, Output, terminal 24K1 Note error warning Call service Error at Sercos bus terminal, Output, terminal 26K1 Note error warning Call service Error at Sercos bus terminal, Power supply, terminal 26K2 Note error warning Call service Error at Sercos bus terminal, Output, terminal 27K1 Note error warning Call service Error at Sercos bus terminal, Output, terminal 28K1 Note error warning Call service Swith On again the motor Motor protection switch or fuse was protection switch released due to an overload Check fuse: If it is defective, replace it Protection fuse for I/O terminals was released. Check fuse: If it is defective, replace it. Protection fuse for fans at the drying belt was released. Check fuse: If it is defective, replace it. Protection fuse for the covers fans Check fuse: If it is defective, was released. replace it. Emergency stop button was pressed Release the Emergency Stop button, and press the RUN button on the machine panel. The safety door is opened. Close safety door No air pressure or air pressure too low Check air supply: - Pressure must be 6 bar at air limiter unit. - Pressure at heating roller must be at minimum 2.5 bar. Error on automatic height adjustment system Switch off the machine and check if there is no mechanical problem Switch machine on again. User Manual 58

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

iFOIL S
7.Machine error code and
troubleshooting
User Manual
58
7.
MACHINE ERROR CODE AND TROUBLESHOOTING
7.1
Machine error code
Code
Description
Cause
Solution
1
Error Sercos bus
module 21K2 PS
Error at Sercos bus terminal,
Power supply, terminal 21K2
Note error warning
Call service
2
Error Sercos bus
module 21K3 AI
Error at Sercos bus terminal,
Analog input, terminal 21K3
Note error warning
Call service
3
Error Sercos bus
module 29K1 AO
Error at Sercos bus terminal,
Analog output, terminal 29K1
Note error warning
Call service
4
Error Sercos bus
module 22K1 AO
Error at Sercos bus terminal,
Analog output, terminal 22K1
Note error warning
Call service
5
Error Sercos bus
module 22K2 In
Error at Sercos bus terminal, Input,
terminal 22K2
Note error warning
Call service
6
Error Sercos bus
module 23K1 In
Error at Sercos bus terminal, Input,
terminal 23K1
Note error warning
Call service
7
Error Sercos bus
module 24K1 In
Error at Sercos bus terminal,
Output, terminal 24K1
Note error warning
Call service
8
Error Sercos bus
module 26K1 Out
Error at Sercos bus terminal,
Output, terminal 26K1
Note error warning
Call service
9
Error Sercos bus
module 26K2 PS
Error at Sercos bus terminal,
Power supply, terminal 26K2
Note error warning
Call service
10
Error Sercos bus
module 27K1 Out
Error at Sercos bus terminal,
Output, terminal 27K1
Note error warning
Call service
11
Error Sercos bus
module 28K1 Out
Error at Sercos bus terminal,
Output, terminal 28K1
Note error warning
Call service
12
Mot. prot. fuse
released
Motor protection switch or fuse was
released due to an overload
Swith On again the motor
protection switch
Check fuse: If it is defective,
replace it
13
Fuse IO released
Protection fuse for I/O terminals
was released.
Check fuse: If it is defective,
replace it.
14
Fuse fan belt
released
Protection fuse for fans at the
drying belt was released.
Check fuse: If it is defective,
replace it.
15
Fuse fan door
released
Protection fuse for the covers fans
was released.
Check fuse: If it is defective,
replace it.
16
Emergency stop
Emergency stop button was
pressed
Release the Emergency Stop
button, and press the RUN button
on the machine panel.
17
Safety door open
The safety door is opened.
Close safety door
18
No air pressure
No air pressure or air pressure too
low
Check air supply:
- Pressure must be 6 bar at air
limiter unit.
- Pressure at heating roller must
be at minimum 2.5 bar.
20
Gap adjustment
error
Error on automatic height
adjustment system
Switch off the machine and check
if there is no mechanical problem
Switch machine on again.