iFOIL S 7.Machine error code and troubleshooting 7. MACHINE ERROR CODE AND TROUBLESHOOTING 7.1 Machine error code Code Description 1 Error Sercos bus module 21K2 PS 2 Error Sercos bus module 21K3 AI 3 Error Sercos bus module 29K1 AO 4 Error Sercos bus module 22K1 AO 5 Error Sercos bus module 22K2 In 6 Error Sercos bus module 23K1 In 7 Error Sercos bus module 24K1 In 8 Error Sercos bus module 26K1 Out 9 Error Sercos bus module 26K2 PS 10 Error Sercos bus module 27K1 Out 11 Error Sercos bus module 28K1 Out 12 Mot. prot. fuse released 13 Fuse IO released 14 Fuse fan belt released 15 Fuse fan door released 16 Emergency stop 17 Safety door open 18 No air pressure 20 Gap adjustment error Cause Error at Sercos bus terminal, Power supply, terminal 21K2 Solution Note error warning Call service Error at Sercos bus terminal, Analog input, terminal 21K3 Note error warning Call service Error at Sercos bus terminal, Analog output, terminal 29K1 Note error warning Call service Error at Sercos bus terminal, Analog output, terminal 22K1 Note error warning Call service Error at Sercos bus terminal, Input, Note error warning terminal 22K2 Call service Error at Sercos bus terminal, Input, Note error warning terminal 23K1 Call service Error at Sercos bus terminal, Output, terminal 24K1 Note error warning Call service Error at Sercos bus terminal, Output, terminal 26K1 Note error warning Call service Error at Sercos bus terminal, Power supply, terminal 26K2 Note error warning Call service Error at Sercos bus terminal, Output, terminal 27K1 Note error warning Call service Error at Sercos bus terminal, Output, terminal 28K1 Note error warning Call service Swith On again the motor Motor protection switch or fuse was protection switch released due to an overload Check fuse: If it is defective, replace it Protection fuse for I/O terminals was released. Check fuse: If it is defective, replace it. Protection fuse for fans at the drying belt was released. Check fuse: If it is defective, replace it. Protection fuse for the covers fans Check fuse: If it is defective, was released. replace it. Emergency stop button was pressed Release the Emergency Stop button, and press the RUN button on the machine panel. The safety door is opened. Close safety door No air pressure or air pressure too low Check air supply: - Pressure must be 6 bar at air limiter unit. - Pressure at heating roller must be at minimum 2.5 bar. Error on automatic height adjustment system Switch off the machine and check if there is no mechanical problem Switch machine on again. User Manual 58