Lenovo E200 Hardware Maintenance Manual (HMM) - 3000 E200 (type 7848) - Page 60

Diagnostic, error, codes

Page 60 highlights

Diagnostic error codes Refer to the following diagnostic error codes when using the diagnostic tests. See "Running tests" on page 44 for the specific type for information about the Diagnostic programs. In the following index, X can represent any number. Diagnostic Error Code 000-000-XXX BIOS Test Passed 000-002-XXX BIOS Timeout 000-024-XXX BIOS Addressing test failure 000-025-XXX BIOS Checksum Value error 000-026-XXX FLASH data error 000-027-XXX BIOS Configuration/Setup error 000-034-XXX BIOS Buffer Allocation failure 000-035-XXX BIOS Reset Condition detected 000-036-XXX BIOS Register error 000-038-XXX BIOS Extension failure 000-039-XXX BIOS DMI data error 000-195-XXX BIOS Test aborted by user FRU/Action No action 1. Flash the system. See "Flash update procedures" on page 111 2. System board 1. Flash the system. See "Flash update procedures" on page 111 2. System board 1. Flash the system. See "Flash update procedures" on page 111 2. System board 1. Flash the system. See "Flash update procedures" on page 111 2. System board 1. Run Setup 2. Flash the system. See "Flash update procedures" on page 111 3. System board 1. Reboot the system 2. Flash the system. See "Flash update procedures" on page 111 3. Run memory test 4. System board 1. Flash the system. See "Flash update procedures" on page 111 2. System board 1. Flash the system. See "Flash update procedures" on page 111 2. System board 1. Flash the system. See "Flash update procedures" on page 111 2. Adapter card 3. System board 1. Flash the system. See "Flash update procedures" on page 111 2. System board Information only Re-start the test, if necessary 54 Lenovo E200 Hardware Maintenance Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

Diagnostic
error
codes
Refer
to
the
following
diagnostic
error
codes
when
using
the
diagnostic
tests.
See
“Running
tests”
on
page
44
for
the
specific
type
for
information
about
the
Diagnostic
programs.
In
the
following
index,
X
can
represent
any
number.
Diagnostic
Error
Code
FRU/Action
000-000-XXX
BIOS
Test
Passed
No
action
000-002-XXX
BIOS
Timeout
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
2.
System
board
000-024-XXX
BIOS
Addressing
test
failure
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
2.
System
board
000-025-XXX
BIOS
Checksum
Value
error
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
2.
System
board
000-026-XXX
FLASH
data
error
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
2.
System
board
000-027-XXX
BIOS
Configuration/Setup
error
1.
Run
Setup
2.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
3.
System
board
000-034-XXX
BIOS
Buffer
Allocation
failure
1.
Reboot
the
system
2.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
3.
Run
memory
test
4.
System
board
000-035-XXX
BIOS
Reset
Condition
detected
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
2.
System
board
000-036-XXX
BIOS
Register
error
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
2.
System
board
000-038-XXX
BIOS
Extension
failure
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
2.
Adapter
card
3.
System
board
000-039-XXX
BIOS
DMI
data
error
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
111
2.
System
board
000-195-XXX
BIOS
Test
aborted
by
user
Information
only
Re-start
the
test,
if
necessary
54
Lenovo
E200
Hardware
Maintenance
Manual