AVAILABLE CONDUIT ACCESS FOR THE ELECTRICAL BOX The accessory tray is equipped with several 1-1/2" pass-through holes as well as 3/4" and 1" knock outs for conduit connectors. The electrical box is equipped with 3/4" and 1" knock outs for conduit connectors. ON/OFF SWITCH POWER WIRING NOTES: Before running power wiring refer to wiring specifications on page 8 for correct wire gauges. Secure all electrical power connections inside the disconnect switch electrical box. Refer to electrical wiring diagrams on pages 29-32. SINGLE PHASE All single phase 115V/208/230V operators will have the following: • L1 WHITE • L2 BLACK • GROUND, GREEN USE1C1O5PPVEROCOLNTDU1CTPORHO.NLY 115V SINGLE PHASE POWER SWITCH ASSEMBLY THREE PHASE All three phase operators will have the following: • L1 BLACK • L2 BLACK • L3 BLACK • GROUND, GREEN USE1C1O5PPVEROCOLNTDU1CTPORHO.NLY 208V/230V SINGLE PHASE AND ALL THREE PHASE POWER SWITCH ASSEMBLY IMPORTANT NOTE: This operator is shipped from the factory as a right hand mounted unit, the unit MUST be phased correctly. On three phase operators, power connections must be properly phased. If phased incorrectly, the gate operator will run reversed. To correct this situation, shut off power at main power source and at the operators electrical disconnect switch. Then reverse any two of the three power leads. MANUAL DISCONNECT MODEL SL585 DISENGAGEMENT: RE-ENGAGEMENT: Rotate disconnect handle 90˚ to disengage. The gate may now be moved manually. Rotate handle back to original position. (Some operator output sprocket rotation may be required for engagement.) MODEL SL595 DISENGAGEMENT: RE-ENGAGEMENT: Open the hinged door and pull the disconnect lever and lock it in place. The gate my now be moved manually. Release the lever and close the door. (Some operator output sprocket rotation may be required for engagement.) Pull the handle to release 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

12
IMPORTANT NOTE:
This operator is shipped from the factory as a right hand mounted unit, the unit MUST be phased correctly.
On three phase operators, power connections must be properly phased. If phased incorrectly, the gate operator will run reversed.
To correct this situation, shut off power at main power source and at the operators electrical disconnect switch. Then reverse any two
of the three power leads.
AVAILABLE CONDUIT ACCESS FOR THE ELECTRICAL BOX
The accessory tray is equipped with several 1-1/2" pass-through holes as well as 3/4" and 1" knock outs for conduit connectors.
The electrical box is equipped with 3/4" and 1" knock outs for conduit connectors.
ON/OFF SWITCH POWER WIRING
NOTES:
Before running power wiring refer to wiring specifications on page 8 for correct wire gauges. Secure all electrical power
connections inside the disconnect switch electrical box. Refer to electrical wiring diagrams on pages 29-32.
MANUAL DISCONNECT
115 VOLT 1 PH.
USE COPPER CONDUCTOR ONLY
115 VOLT 1 PH.
USE COPPER CONDUCTOR ONLY
115V SINGLE PHASE
POWER SWITCH ASSEMBLY
208V/230V SINGLE PHASE
AND ALL THREE PHASE
POWER SWITCH ASSEMBLY
Pull the handle
to release
MODEL SL595
DISENGAGEMENT:
Open the hinged door and pull the
disconnect lever and lock it in place.
The gate my now be moved manually.
RE-ENGAGEMENT:
Release the lever and close the door.
(Some operator output sprocket
rotation may be required for
engagement.)
MODEL SL585
DISENGAGEMENT:
Rotate disconnect handle 90˚ to
disengage. The gate may now be
moved manually.
RE-ENGAGEMENT:
Rotate handle back to original
position. (Some operator output
sprocket rotation may be required for
engagement.)
SINGLE PHASE
All single phase
115V/208/230V
operators will have the
following:
• L1 WHITE
• L2 BLACK
• GROUND, GREEN
THREE PHASE
All three phase operators will have the following:
• L1 BLACK
• L2 BLACK
• L3 BLACK
• GROUND, GREEN