LiftMaster SL595 SL595 Manual - Page 15

Ul325 Entrapment Protection (continued), Control Board Illustration, Edge/photo Close - gate opener

Page 15 highlights

UL325 ENTRAPMENT PROTECTION (CONTINUED) EDGE/PHOTO OPEN This switch (S2-3) selects edge or photo sensor for the gate opening protection input. PHOTO OPEN CLED OPED WARN MAG Open Photo Eye (Pause): When the S2 control board is configured for photo ON eyes, the input functions to pause the gate ON during the opening cycle. Once the input 1 2 34 is cleared the gate continues to open. PH PH Shown as factory default. EDGE OPEN CLED OPED WARN MAG Open Edge: When the control board is S2 configured for safety edges, the input ON functions to reverse the gate to the close ON limit when the edge is activated during the 1 2 34 PH PH opening cycle. EDGE/PHOTO CLOSE This switch (S2-4) selects edge or photo sensor for the gate closing protection input. PHOTO CLOSE CLED OPED WARN MAG Close Photo Eye (Reverse): When the S2 control board is configured for photo eyes, the input functions to reverse the gate to ON the open limit when activated during the ON close cycle. Shown as factory default. 1 2 34 PH PH NOTE: Timer-to-Close will reset if enabled. Close Edge: When the control board is configured for safety edges, the input EDGE CLOSE CLED OPED WARN MAG functions to reverse the gate to the open S2 limit when activated during the close cycle. ON The entrapment is not cleared at the limit and the Timer-to-Close will be disabled. The Timer-to-Close may be enabled by ON 1 2 34 PH PH activating the interrupt (safety) loop, open or override open inputs. CONTROL BOARD ILLUSTRATION Main Terminal Wiring J4 Connector Master/Second Dip Switch #4 Master/Second Potentiometer Timer-to-Close Potentiometer Force Adjustment Dip Switch #2 Dip Switch #1 Diagnostic LED J2 Connector J5 Connector SAMS Relay Drive Troubleshooting LEDs J1 Terminal Troubleshooting LEDs 15 Limit LEDs Programming Port (factory use only) Motor Learn Button J3 Connector Aux. Relay Drive (not used)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Relay Drive
Troubleshooting LEDs
J1 Terminal
Troubleshooting LEDs
J5 Connector
SAMS
J2 Connector
J3 Connector
Aux. Relay Drive
(not used)
Motor Learn
Button
Programming Port
(factory use only)
Limit LEDs
Main Terminal
Wiring
Potentiometer
Timer-to-Close
Dip Switch #4
Master/Second
J4 Connector
Master/Second
Diagnostic LED
Dip Switch #2
Dip Switch #1
Potentiometer
Force Adjustment
15
EDGE/PHOTO CLOSE
This switch (S2-4) selects edge or photo sensor for the gate
closing protection input.
Close Photo Eye (Reverse):
When the
control board is configured for photo eyes,
the input functions to reverse the gate to
the open limit when activated during the
close cycle.
Shown as factory default.
NOTE:
Timer-to-Close will reset if enabled.
Close Edge:
When the control board is
configured for safety edges, the input
functions to reverse the gate to the open
limit when activated during the close cycle.
The entrapment is not cleared at the limit
and the Timer-to-Close will be disabled.
The Timer-to-Close may be enabled by
activating the interrupt (safety) loop, open
or override open inputs.
UL325 ENTRAPMENT PROTECTION (CONTINUED)
CONTROL BOARD ILLUSTRATION
EDGE/PHOTO OPEN
This switch (S2-3) selects edge or photo sensor for the gate
opening protection input.
Open Photo Eye (Pause):
When the
control board is configured for photo
eyes, the input functions to pause the gate
during the opening cycle. Once the input
is cleared the gate continues to open.
Shown as factory default.
Open Edge:
When the control board is
configured for safety edges, the input
functions to reverse the gate to the close
limit when the edge is activated during the
opening cycle.
ON
CLED
PH
OPED
PH
1
2
3
4
WARN
MAG
ON
S2
ON
CLED
PH
OPED
PH
1
2
3
4
WARN
MAG
ON
S2
ON
CLED
PH
OPED
PH
1
2
3
4
WARN
MAG
ON
S2
ON
CLED
PH
OPED
PH
1
2
3
4
WARN
MAG
ON
S2
PHOTO OPEN
EDGE OPEN
PHOTO CLOSE
EDGE CLOSE