LiftMaster SL595 SL595 Manual - Page 32
Three Phase Wiring Schematic
View all LiftMaster SL595 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
THREE PHASE SCHEMATIC YELLOW W A R N I N G To protect against fire and electrocution: • DISCONNECT power BEFORE installing or servicing operator. BLACK (SL595 ORANGE) AUXILIARY RELAY • Replace ONLY with fuse of same type and rating. Fuse: 3AG, 3.2A, 120V, SLO-BLO SEE NOTE 5 EXTERNAL OVERLOAD MOTOR SEE NOTE 3 TO J2-1 PURPLE Y (SL595 WHT) CONTACTOR A1 B A2 13 14 5 6 TB2-CD BLACK OVERLOAD BK LINE LOAD YELLOW 24VAC/60VA BLUE FUSE 3.2A YELLOW GY (SL595 GN) 3 4 PU (SL595 RD) 1 2 WHITE XFMR ON/OFF WHITE SWITCH (TB2) AB CD L1 BK ON L2 BK POWER IN OFF L3 SEE NOTE 1 BK YELLOW BLUE TO J2-2 TO MOTOR ORANGE A1 13 5 3 1 230V CONNECTION BL-BK GY 174 BK PU 28 5 BK Y 3 96 SEE NOTE 5 BL-BK 230V BRAKE SOLENOID A2 14 6 4 A2 L/S "AC"NC BK BK BK 1 SEE NOTE 5 EXTERNAL OVERLOAD ORANGE PURPLE GROUND GREEN CONTACTOR A A1 G RPM BOARD BLACK RED WHITE ORANGE CONTACTOR B A1 PURPLE J2 PLUG ON PCB 11 10 9 8 7 6 5 4 3 2 1 BLUE YELLOW RADIO TERMINAL BLOCK OR PU 460V CONNECTION GY 174 BK PU 2 85 BK Y 396 SEE NOTE 5 BL-BK BL-BK 230V BRAKE SOLENOID 575V CONNECTION GY 1 BK PU 2 BK Y SEE NOTE 5 3 BL-BK BL-BK 575V BRAKE SOLENOID RADIO SHADOW VDC COM CLOSE STOP SOFT OPEN HARD OPEN INTERRUPT YEL/BLK L/S "BC"NC 2 Y/BK R1 TB1-15 BLUE R2 24 VAC ALARM BLACK R3 3 Y/BK TB1-3 Y/BK R4 TB1-6 BROWN RADIO SIGNAL FREE EXIT LOOP 4 GREEN FIELD CONNECTIONS OPEN CLOSE MASTER EDGE/PHOTO SECOND EYE 24 VAC ACCESSORY POWER MAGLOCK INTERRUPT LOOP (SEE NOTE 6) FACTORY INSTALLED RADIO EXIT LOOP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 PURPLE PUR/WHT YEL/BLK GREEN STOP RESET BROWN ORANGE GREEN GRAY OR/BLK WHITE RED BLACK BLACK BLUE R1 BLUE LOOP WIRING (TB1) YELLOW (See NOTE 6) R4 TB1-5 TB2-CD TB2-AB TB2-20 TB2-19 TB1-8 TB1-3 TB2-CD TB2-AB TB2-18 TB2-17 4 6 FREE EXIT 7 LOOP 8 HARNESS 9 (10 PIN) 10 4 6 INTERRUPT 7 LOOP 8 HARNESS 9 (10 PIN) 10 J1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 J4 1 2 J2 - R2 BK + RD (100db) SAFETY ALARM TB1-5 J1-5 OPEN Y/BK OR CLOSE Y/BK GRN STOP Y/BK Y/BK Y/BK RESET TB1-7 TB1-4 TB1-5 NOTES: 1. Voltage: 208/230/460/575 volt 3 phase. 2. Horsepower: 1/2, 1 & 2 HP. 3. Transformer primary voltage is the same as the operator line voltage. Secondary 24v/60va. (GL CONTROL BOARD) For reference primary wire colors: 120v black, 208v red, 230v orange, 460v purple, 575v grey 4. Terminal block in limit switch enclosure (SL595 only). 5. Three phase units are equipped with an internal pilot duty thermal overload device or an external line monitoring system. 6. When using a remote control or single button control station in lieu of the soft open feature, perform the following modifications to the operator: • Remove the green wire from R4 of the radio block and mount the wire to terminal block TB1 position 6. • Move the brown wire on terminal block TB1 position 6 (from radio block R4) to terminal block TB1 position 1. 32 40-32357J