Maytag MED6300TQ Use and Care Guide - Page 17

Install

Page 17 highlights

Determine vent path • Select the route that will provide the straightest and most direct path outdoors. • Plan the installation to use the fewest number of elbows and turns. • When using elbows or making turns, allow as much room as possible. • Bend vent gradually to avoid kinking. • Use the fewest 90 ° turns possible. Determine vent length and elbows needed for best drying performance • Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will: • Shorten the life of the dryer. • Reduce performance, resulting in longer drying times and increased energy usage. The Vent system chart provides venting requirements that will help to achieve the best drying performance. Vent system chart NOTE: Performance of rear exhaust to either side of the dryer is equiw_lent to adding one elbow. To determine maximum exhaust length, add one elbow to the chart. Number of 90 ° turns or elbows Type of vent Box or Louvered hoods Angled hoods 0 Rigid metal 64 ft (20 m) 58 ft (17.7 m) Flexible metal 36 ft (11 m) 28 ft (8.5 m/ 1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m) Flexible metal 31 ft (9.4 m) 23 ft (7 m) 2 Rigid metal 44 ff (13.4 m) 38 ft (11.6 m) Flexible metal 27 ff (8.2 m) 19 ft (5.8 m/ 3 Rigid metal 35 ff (10.7 m) 29 ft (8.8 m) Flexible metal 25 ff (7.6 m) 17 ft (5.2 m/ 4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m) Flexible metal 23 ft 17 m) 15 ft (4.6 m) INSTALL VENT SYSTEM 1. install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood. 2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp. 3. Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in "Plan Vent System." Avoid 90 ° turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent. INSTALL LEVELING LEGS Excessive Weight Hazard Use two or more people to move and install dryer. Failure to do so can result in back or other injury. 1. lb protect the floor, use a large, flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer. 2. Firmly grasp the body of the dryer (not the top or console panel). Gently lay the dryer on the cardboard. See illustration. Examine the leveling legs. Find the diamond marking. 4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible. 5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Determine
vent
path
Select
the
route
that
will
provide
the
straightest
and
most direct
path
outdoors.
Plan the
installation
to
use the
fewest
number
of
elbows
and
turns.
When
using
elbows
or making
turns,
allow
as much
room
as possible.
Bend
vent
gradually
to avoid
kinking.
Use the fewest
90 ° turns
possible.
Determine
vent
length
and
elbows
needed
for
best
drying
performance
Use the following
Vent
system
chart
to determine
type
of vent
material
and
hood
combinations
acceptable
to use.
NOTE:
Do
not
use vent
runs
longer
than
those
specified
in the Vent
system
chart.
Exhaust
systems
longer
than
those
specified
will:
Shorten
the
life
of the
dryer.
Reduce
performance,
resulting
in longer
drying
times
and
increased
energy
usage.
The Vent
system
chart
provides
venting
requirements
that
will
help
to achieve
the
best drying
performance.
Vent
system
chart
NOTE:
Performance
of
rear exhaust
to either
side
of the
dryer
is equiw_lent
to adding
one
elbow.
To determine
maximum
exhaust
length,
add
one
elbow
to the
chart.
Number
of 90 °
Type of vent
Box or
Louvered
Angled
hoods
turns
or elbows
hoods
0
Rigid metal
64 ft (20
m)
58 ft (17.7
m)
Flexible
metal
36 ft (11
m)
28 ft (8.5
m/
1
Rigid metal
54 ft (16.5
m)
48 ft (14.6
m)
Flexible
metal
31 ft (9.4
m)
23 ft (7 m)
2
Rigid metal
44 ff (13.4
m)
38 ft (11.6
m)
Flexible
metal
27 ff (8.2
m)
19 ft (5.8
m/
3
Rigid metal
35 ff (10.7
m)
29 ft (8.8
m)
Flexible
metal
25 ff (7.6
m)
17 ft (5.2 m/
4
Rigid metal
27 ft (8.2
m)
21 ft (6.4
m)
Flexible
metal
23 ft 17 m)
15 ft (4.6
m)
INSTALL
VENT
SYSTEM
1.
install
exhaust
hood.
Use
caulking
compound
to seal
exterior
wall
opening
around
exhaust
hood.
2.
Connect
vent to exhaust
hood.
Vent
must fit
inside
exhaust
hood.
Secure
vent
to exhaust
hood
with
4" (10.2
cm)
clamp.
3.
Run vent
to dryer
location.
Use the straightest
path possible.
See "Determine
vent
path"
in
"Plan
Vent
System."
Avoid
90 ° turns.
Use clamps
to seal
all joints.
Do
not
use duct
tape,
screws
or other
fastening
devices
that
extend
into
the
interior
of the
vent to
secure
vent.
INSTALL
LEVELING
LEGS
Excessive
Weight
Hazard
Use
two
or more
people
to
move
and
install
dryer.
Failure
to do so
can
result
in back
or other
injury.
1.
lb
protect
the floor,
use a large,
flat piece
of cardboard
from
the
dryer
carton.
Place
cardboard
under
the
entire
back
edge
of the
dryer.
2.
Firmly
grasp
the
body
of the
dryer
(not
the top
or console
panel).
Gently
lay the
dryer
on
the
cardboard.
See illustration.
Examine
the
leveling
legs.
Find the
diamond
marking.
4.
Screw
the
legs into
the
leg holes
by hand.
Use a wrench
to finish
turning
the
legs until
the
diamond
marking
is no
longer
visible.
5.
Place
a carton
corner
post from
dryer
packaging
under
each
of the
2 dryer
back
corners.
Stand the
dryer
up. Slide
the
dryer
on the
corner
posts
until
it is close
to its final
location.
Leave enough
room
to connect
the exhaust
vent.