Daisy-chaining Your monitors
View all NEC PX-50VP1A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Daisy-chaining Your monitors The REMOTE IN/OUT terminals allow you to control multiple monitors using one remote control. 1. Connect the REMOTE OUT of the monitor to the RE- MOTE IN of the next monitor using the optional remote cable. When using the VIDEO inputs: THROUGH OUT Connections 1. To pass the VIDEO IN (BNC-type) or S-VIDEO signals, connect THROUGH OUT BNC or S-VIDEO to the external equipment. When using the RGB2 Input: THROUGH OUT Connections 1. To pass the RGB2 signal, connect the THROUGH OUT RGBH/V (RGBCS) to the external equipment. Note: "Plug and Play" is not available for the RGB2 BNC terminals. Note: In order to make sure that there is no signal loss, do not loop out to more than 3 other devices (maximum 4 units when taking the first unit into consideration). Note: When looping from one unit to the next, make sure that the 75ohm termination switch is set only on the last unit. All other units should be set in the HIGH position. 21