Other Setting Screens (2) This allows the following settings: LONG LIFE MODE 1/ 2/3 GRAY LEVEL, SET ID NO, and ALL RESET. 1. Align the cursor with icon (14) of the second page. The cursor is moved left and right with the POSITION CONTROLᮤ / ᮣ buttons. Icon (14) LONG LIFE MODE 1 LONG LIFE MODE 2 LONG LIFE MODE 3 GRAY LEVEL SET ID NO RGB3 ADJ : OFF : OFF : OFF : 1 : ALL : 1 ALL RESET 2. Align the cursor with the desired item POSITION / CONTROL Move up Move down LONG LIFE MODE 1 LONG LIFE MODE 2 LONG LIFE MODE 3 GRAY LEVEL SET ID NO RGB3 ADJ : OFF : OFF : OFF : 1 : ALL : 1 ALL RESET Notice - About RGB3 ADJ If the image is not stable when in the RGB3 input mode, switch the "RGB3 ADJ" number to 2 or 3. (Select the mode at which the display is stable.) The display position will change when the number is changed; therefore, when using the unit with "AUTO PICTURE" ON, switch it OFF and then back ON again to return the display position to its original location. When using the unit with "AUTO PICTURE" OFF, please perform the display position adjustment again. 3. Press the v / w buttons and set Select the various items with the left and right buttons Burning reduction function * LONG LIFE MODE 1: Switched ON/OFF with the left and right buttons. (Initial value is OFF) → Holds down the brightness of the screen. * LONG LIFE MODE 2: Switched ON/OFF with the left and right buttons. (Initial value is OFF) → Moves the screen up, down, left, and right at fixed times. * LONG LIFE MODE 3: Switched INV/WT/OFF with the left and right buttons. (Initial value is OFF) → Selecting "INV"displays the inverse image of the in coming signal to reduce burn-in. * Selecting "WT" displays the all white pattern to reduce image burn-in. Note: The long life mode is designed to extend the service life of the plasma panel and reduce ghost images. It is not meant to prevent ghost images. LONG LIFE MODE 2 cannot be set with multiple screens operation. Switching to GAMMA is not possible when LONG LIFE MODE3 is set LONG LIFE MODE 3: When the plasma monitor is turned on or off, the INV. WT setting is set to OFF and the last data is not stored in memory. * GRAY LEVEL: Select 1 to 3 with the left and right buttons. (Initial value is 1) → Adjusts the brightness of the non-displayed portion of the screen. * SET ID No.: Select 1 to 256 with the left and right buttons. (Initial value is ALL) → Displays ALL with the remote control or CLEAR button. Note: Selecting ALL RESET and pressing the PROCEED button will display a warning screen and pressing "PROCEED" further will change all the settings of this screen to the initial values. 4. Return to the main menu EXIT * To delete the main menu, press the EXIT button once more. * Align the cursor with icon (15) at the very top to move to the first page menu screen. Previous Page Screen Icon (15) SOURCE INFO. RGB1 H-FREQ. V-FREQ. H-POL. V-POL. 31.5kHz 60.0Hz NEG POS 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

45
Other Setting Screens (2)
This allows the following settings: LONG LIFE MODE 1/
2/3 GRAY LEVEL, SET ID NO, and ALL RESET.
1.
Align the cursor with icon (14) of the second page.
Icon (14)
The cursor is moved left and right with the POSITION
CONTROL
§
/
'
buttons.
2.
Align the cursor with the desired item
POSITION / CONTROL
Move up
Move down
Note:
Selecting ALL RESET and pressing the
PROCEED button will display a warning screen and
pressing “PROCEED” further will change all the
settings of this screen to the initial values.
3.
Press the
/
buttons and set
Select the various items with the left and right buttons
Burning reduction function
* LONG LIFE MODE 1: Switched ON/OFF with the
left and right buttons. (Initial value is OFF)
Holds
down the brightness of the screen.
* LONG LIFE MODE 2: Switched ON/OFF with the
left and right buttons. (Initial value is OFF)
Moves
the screen up, down, left, and right at fixed times.
*
LONG LIFE MODE 3: Switched INV/WT/OFF with
the left and right buttons. (Initial value is OFF)
Selecting “INV”displays the inverse image of the in
coming signal to reduce burn-in.
* Selecting “WT” displays the all white pattern to re-
duce image burn-in.
* GRAY LEVEL: Select 1 to 3 with the left and right
buttons. (Initial value is 1)
Adjusts the brightness
of the non-displayed portion of the screen.
* SET ID No.: Select 1 to 256 with the left and right
buttons. (Initial value is ALL)
Displays ALL with
the remote control or CLEAR button.
4.
Return to the main menu
*
To delete the main menu, press the EXIT button once
more.
EXIT
LONG LIFE MODE 1
LONG LIFE MODE 2
LONG LIFE MODE 3
GRAY LEVEL
SET ID NO
RGB3 ADJ
ALL RESET
: OFF
: OFF
: OFF
: 1
: ALL
: 1
LONG LIFE MODE 1
LONG LIFE MODE 2
LONG LIFE MODE 3
GRAY LEVEL
SET ID NO
RGB3 ADJ
ALL RESET
: OFF
: OFF
: OFF
: 1
: ALL
: 1
Previous Page Screen
Icon (15)
*
Align the cursor with icon (15) at the very top to move
to the first page menu screen.
SOURCE INFO.
RGB1
H-FREQ.
V-FREQ.
H-POL.
V-POL.
31.5kHz
60.0Hz
NEG
POS
Notice - About RGB3 ADJ
If the image is not stable when in the RGB3 input mode,
switch the “RGB3 ADJ” number to 2 or 3.
(Select the
mode at which the display is stable.)
The display position will change when the number is
changed; therefore, when using the unit with “AUTO PIC-
TURE” ON, switch it OFF and then back ON again to re-
turn the display position to its original location.
When using the unit with “AUTO PICTURE” OFF,
please perform the display position adjustment again.
Note:
The long life mode is designed to extend the
service life of the plasma panel and reduce ghost im-
ages.
It is not meant to prevent ghost images.
LONG LIFE MODE 2 cannot be set with multiple
screens operation.
Switching to GAMMA is not possible when LONG
LIFE MODE3 is set
LONG LIFE MODE 3: When the plasma monitor
is turned on or off, the INV. WT setting is set to
OFF and the last data is not stored in memory.