Oki MICROLINE 390 TURBO Printer Handbook - Page 114

Oki MICROLINE 390 TURBO Manual

Page 114 highlights

IBM Function Proportional Spacing Set 10 Cpi Pitch Set 12 Cpi Pitch Set 15 Cpi Pitch Set Compressed Pitch Commands (ASCII, Decimal, Hexadecimal) Notes ASCII: ESC P n Dec: 27 80 n Hex: 1B 50 n ASCII: DC2 Dec: 18 Hex: 12 ASCII: ESC : Dec: 27 58 Hex: 1B 3A ASCII: ESC g Dec: 27 103 Hex: 1B 67 ASCII: SI Dec: 15 hex: 0F Pn0=3: specifies the number of parameters (in bytes) to follow Character Pitch m=0: unchanged m=1: Proportional m>5: m/360 inch Point size=(n1 + [n2 x 256]) x 0.5 point Point size can be selected between a minimum of 8 point to a maximum of 64 point. Engages/ cancels proportional spacing n=0 to 255: n is odd number: start proportional spacing n is even number: stop proportional spacing When printer is in utility mode, this command will switch it to LQ proportional until it is canceled. This is standard pica typewriter size. Changes to 12 cpi except if Menu item "SI Select (12 CPI)" is set to "20", then ESC: will change 17.1 cpi to 20 cpi and will not change 20 cpi. OKI unique command. Sets 15 cpi. Condenses cpi as follows (depending on MENU setting for SI Select Pitch): 10 cpi: 15 cpi for SI=10; 17.1 cpi for SI=12 12 cpi: 12 cpi for SI=10; 20 cpi for SI=12 15 cpi: 15 cpi for SI=10; 17.1 cpi for SI=12 17.1 cpi: 15 cpi for SI=10; 17.1 cpi for SI=12 20 cpi: 15 cpi for SI=10;17.1 cpi or 20 cpi for SI=12 ML390/391 Turbo Printer Handbook 107

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

ML390/391 Turbo Printer Handbook
107
Proportional Spacing
Set 10 Cpi Pitch
Set 12 Cpi Pitch
Set 15 Cpi Pitch
Set Compressed Pitch
ASCII: ESC P n
Dec: 27 80 n
Hex: 1B 50 n
ASCII: DC2
Dec: 18
Hex: 12
ASCII: ESC :
Dec: 27 58
Hex: 1B 3A
ASCII: ESC g
Dec: 27 103
Hex: 1B 67
ASCII: SI
Dec: 15
hex: 0F
IBM
Function
Commands
(ASCII, Decimal, Hexadecimal)
P
n0
=3: specifies the number of parame-
ters (in bytes) to follow
Character Pitch
m=0: unchanged
m=1: Proportional
m>5: m/360 inch
Point size=(n
1
+ [n
2
x 256]) x 0.5 point
Point size can be selected between a
minimum of 8 point to a maximum
of
64 point.
Engages/ cancels proportional spacing
n=0 to 255:
n is odd number: start proportional
spacing
n is even number: stop proportional
spacing
When printer is in utility mode, this
command will switch it to LQ
propor-
tional until it is canceled.
This is standard pica typewriter size.
Changes to 12 cpi except if Menu item
"SI Select (12 CPI)" is set to "20", then
ESC: will change 17.1 cpi to 20 cpi and
will not change 20 cpi.
OKI unique command. Sets 15 cpi.
Condenses cpi as follows (depending on
MENU setting for SI Select Pitch):
10 cpi: 15 cpi for SI=10; 17.1 cpi
for SI=12
12 cpi: 12 cpi for SI=10; 20 cpi for SI=12
15 cpi: 15 cpi for SI=10; 17.1 cpi for SI=12
17.1 cpi: 15 cpi for SI=10; 17.1 cpi for
SI=12
20 cpi: 15 cpi for SI=10;17.1 cpi or 20 cpi
for SI=12
Notes