Panasonic AJHD1700P AJHD1700 User Guide - Page 77
active low edge, input an electrical signal of 100 ms, For a command, input TTL level signals; for an
![]() |
View all Panasonic AJHD1700P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
Function menus 50-pin assignment factory settings Pin I/O no. Setting item 1 I REC 2 I PLAY 3 I FF 4 I REW 5 I STOP 6 I ___ 7 I ___ 8 I 422 REMOTE ON 9 I 422 REMOTE OFF 10 I LOCAL ENABLE 11 I EJECT 12 I IN SET 13 I REC INH ALL 14 I REC INH PRE 15 I LOCAL DISABLE 16 I TC EXT 17 I TC INT&TCG MODE AUTO 18 I ___ 19 I ___ 20 I STNDBY ON/OFF 21 O ERR0 STATUS 22 I DET STOP ON 23 I CUE 24 O ERR1 STATUS 25 I DET STOP OFF 26 Power 27 O REC STATUS 28 O PLAY STATUS 29 O FF STATUS 30 O REW STATUS 31 O STOP STATUS 32 O 422 REMOTE STATUS 33 O EJECT STATUS 34 O ERR2 STATUS 35 O TC SRC1 STATUS 36 O TC SRC2 STATUS 37 O ___ 38 O ___ 39 O REC INH1 STATUS 40 O REC INH2 STATUS 50P IN/OUT ASSIGN Pin I/O no. Setting item 41 O CUE STATUS 42 O REMOTE STATUS 43 O DET STOP STATUS 44 O PRE CTL DETECTED STATUS 45 O LOCAL ENABLE STATUS 46 O STANDBY ON STATUS 47 GND 48 O ___ 49 GND 50 GND "__" denotes that nothing is subject to control or to a status. • For a command, input TTL level signals; for an active low edge, input an electrical signal of 100 ms or more. • For a status, a maximum open collector and sink current of 6 mA is output. 77