Panasonic AJHD1700P AJHD1700 User Guide - Page 9

Front panel, CH1 + CH2 + CH4

Page 9 highlights

Parts and Their Functions Front panel < 8 9: = ; POWER OFF ON HEADPHONES CH1 2 CH CONDITION 3 4 5 6 7 8 CUE MONITOR FULL/FINE 9P L R REMOTE 50P RS-232C XL/L/M-cassette Do not insert S-cassette without adapter HOME RF1 RF2 ASSEM VIDEO UNITY TC AUDIO UNITY DIAG CUE INSERT MENU ADJUST PUSH-INTER STAND BY PLAYER RECORDER INPUT CHECK AUDIO CH SELECT CH 1 CH 5 CH 2 CH 6 CH 3 CH 7 CH 4 CH 8 FULL REC P8 PUSH LOCK REC P8 REC P8 REC P8 SHIFT F1 F2 ABC DEF GHI 789 JKL MNO PQRS 4 5 6 BS TUV WXYZ 1 2 3 ENT 0CT F F3 F4 F5 F6 A IN PREVIEW/ PRE- REVIEW ROLL A OUT AUTO EDIT TRIM SET IN OUT EDIT REW SERVO PLAY REC INHIBIT REC STOP FF EJECT SHTL JOG VAR REV FWD FULL 8 MONITOR SELECT buttons These buttons are used to select the audio signals which are to be output to the monitor L and R connectors and headphones jack. • When OFF has been selected as the F6 M MIX setting on the menu (factory setting): Each time the L (or R) button is pressed, the signal to be output to the monitor L (or R) connector is changed in the following sequence and displayed on the audio level meter: CH1 > CH2 > CH3> CH4 > CH5 > CH6 > CH7 > CH8 > CUE > CH1, etc. • When L, R or L/R has been selected as the F6 M MIX setting on the menu: At this setting, the signals of a multiple number of channels can be mixed and output. When the number key corresponding to the channel whose signals are to be monitored is pressed while the L (or R) button is held down, that channel is selected and its signals are displayed on the audio level meter. (By performing the same operation, the selected channel can be de-selected.) However, a maximum of only two channels from CH1 to CH4 and a maximum of only two channels from CH5 to CH8 can be selected. Example of channels which can be selected: CH1 i CH3 i CH5 iCH8 " OK CH1 + CH2 + CH4 " NG 9 METER (FULL/FINE) selector button This button is used to select the scale display for the audio level meter. FULL mode: Depending on the setting selected for the setup menu item No.763 (METER SCALE)*, either the j¶ to 0 dB (reference level: j20 dB/j18 dB**) or j¶ to i20 dB (reference level: 0 dB) range is displayed. FINE mode: Depending on the setting selected for the setup menu item No.763 (METER SCALE)*, either the j24 to j15 dB (reference level: j20 dB/j18 dB**) or j4 to i5 dB (reference level: 0 dB) range is displayed on a scale with 0.5 dB increments. * This menu is not displayed for AJ-HD1700E. ** j20 dB is applied for AJ-HD1700P and j18 dB is for AJ-HD1700E. : REMOTE buttons and RS-232C display These buttons are used when this VTR is to be controlled from an external component using the REMOTE, RS-232C or parallel connector. 9P: When this button is pressed for 2 or more seconds, its LED lights, and the 9-pin REMOTE connector is selected. 50P: When this button is pressed for 2 or more seconds, its LED lights, and it is possible to control the VTR from a unit which has been connected using the 50-pin parallel mode connector. RS-232C display: This LED lights when communication has been enabled between the VTR and the unit which has been connected to the RS-232C connector. ; AUTO OFF lamp This lamp lights when a problem has occurred with the VTR's operation, and details of the problem appear on the time code display. < LCD monitor This monitor is used to check the tape's playback pictures and EE pictures. When an HD tape is played back, the signals are downconverted and displayed in the letter-box screen format. When an SD tape is played back, the signals are displayed using a 4:3 aspect ratio. On-screen menus can also be displayed on the monitor. If the VTR is left in a state where no controls on the front panel are operated or where the tape is not running, the monitor display is automatically turned off in order to protect the monitor. When the next VTR operation is started, the monitor display comes back on. Although the LCD monitor has been manufactured using technology with extremely high levels of precision, some pixels may be missing from parts of the screen or some pixels may remain lighted. These missing or lighted pixels will not be recorded. It should also be borne in mind that this is not indicative of a malfunction. = Function buttons These buttons are used to perform the operations of the function menus (see page 38 for details) and setup menus. SHIFT : This is used to switch the pages of the current function menu ( F1 to F6 ). F1 to F6 : These are used to change the settings of the setting items enclosed in the frame at the bottom of the time code display. To change a setting, keep pressing the corresponding function button ( F1 to F6 ) until the desired numerical value appears; alternatively, press the corresponding function button to highlight the setting of the setting item, and then turn the ADJUST dial until the desired numerical value is obtained. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

9
POWER
OFF
ON
HEADPHONES
PUSH
LOCK
FULL
CH CONDITION
MONITOR
FULL/FINE
REMOTE
L
R
9P
50P
RS-232C
CH
1
2
3
4
5
6
7
8
CUE
XL/L/M
-
cassette
Do not insert S-cassette
without adapter
EJECT
AUDIO CH SELECT
SHIFT
ABC
DEF
GHI
JKL
MNO
PQRS
PREVIEW/
REVIEW
PRE-
ROLL
A IN
A OUT
HOME
RF1
ASSEM
ADJUST
SHTL
REV
FWD
VAR
JOG
STAND BY
RECORDER
INPUT CHECK
PLAYER
SERVO
EDIT
PLAY
REC
REW
STOP
FF
REC INHIBIT
PUSH-INTER
INSERT
RF2
VIDEO
UNITY
TC
CUE
AUDIO
UNITY
DIAG
MENU
TRIM
SET
IN
OUT
AUTO
EDIT
7
8
9
4
5
6
BS
TUV
WXYZ
1
2
3
ENT
0
C
T
F
F1
F2
F3
F4
F5
F6
CH
1
CH
5
CH
2
CH
6
CH
3
CH
7
CH
4
CH
8
FULL
REC
P8
REC
P8
REC
P8
REC
P8
<
9
;
8
:
=
Front panel
8
MONITOR SELECT buttons
These buttons are used to select the audio signals
which are to be output to the monitor L and R
connectors and headphones jack.
When OFF has been selected as the
M
MIX setting on the <AUDIO SHIFT2> menu
(factory setting):
Each time the L (or R) button is pressed, the
signal to be output to the monitor L (or R)
connector is changed in the following sequence
and displayed on the audio level meter: CH1
>
CH2
>
CH3
>
CH4
>
CH5
>
CH6
>
CH7
>
CH8
>
CUE
>
CH1, etc.
When L, R or L/R has been selected as the
M MIX setting on the <AUDIO SHIFT2> menu:
At this setting, the signals of a multiple number of
channels can be mixed and output.
When the number key corresponding to the
channel whose signals are to be monitored is
pressed while the L (or R) button is held down,
that channel is selected and its signals are
displayed on the audio level meter.
(By
performing the same operation, the selected
channel can be de-selected.)
However, a maximum of only two channels from
CH1 to CH4 and a maximum of only two
channels from CH5 to CH8 can be selected.
Example of channels which can be selected:
CH1
i
CH3
i
CH5
i
CH8
OK
CH1 + CH2 + CH4
NG
9
METER (FULL/FINE) selector button
This button is used to select the scale display for the
audio level meter.
FULL mode:
Depending on the setting selected for the
setup menu item No.763 (METER SCALE)*, either the
to 0 dB (reference level:
j
20 dB/
j
18 dB**) or
to
i
20 dB (reference level: 0 dB) range is displayed.
FINE mode:
Depending on the setting selected for the
setup menu item No.763 (METER SCALE)*, either the
j
24 to
j
15 dB (reference level:
j
20 dB/
j
18 dB**) or
j
4 to
i
5 dB (reference level: 0 dB) range is displayed
on a scale with 0.5 dB increments.
*
This menu is not displayed for AJ-HD1700E.
**
j
20 dB is applied for AJ-HD1700P and
j
18 dB is for AJ-HD1700E.
F6
F6
Parts and Their Functions
:
REMOTE buttons and RS-232C display
These buttons are used when this VTR is to be
controlled from an external component using the
REMOTE, RS-232C or parallel connector.
9P:
When this button is pressed for 2 or more
seconds, its LED lights, and the 9-pin REMOTE
connector is selected.
50P:
When this button is pressed for 2 or more
seconds, its LED lights, and it is possible to control
the VTR from a unit which has been connected using
the 50-pin parallel mode connector.
RS-232C display:
This LED lights when communi-
cation has been enabled between the VTR and the
unit which has been connected to the RS-232C
connector.
;
AUTO OFF lamp
This lamp lights when a problem has occurred with
the VTR’s operation, and details of the problem
appear on the time code display.
<
LCD monitor
This monitor is used to check the tape’s playback
pictures and EE pictures.
When an HD tape is played back, the signals are down-
converted and displayed in the letter-box screen format.
When an SD tape is played back, the signals are
displayed using a 4:3 aspect ratio.
On-screen menus can also be displayed on the monitor.
If the VTR is left in a state where no controls on the front
panel are operated or where the tape is not running, the
monitor display is automatically turned off in order to
protect the monitor.
When the next VTR operation is
started, the monitor display comes back on.
<Note>
Although the LCD monitor has been manufactured
using technology with extremely high levels of
precision, some pixels may be missing from parts of
the screen or some pixels may remain lighted.
These missing or lighted pixels will not be recorded.
It should also be borne in mind that this is not
indicative of a malfunction.
=
Function buttons
These buttons are used to perform the operations of
the function menus (see page 38 for details) and
setup menus.
:
This is used to switch the pages of the current
function menu (
to
).
to
:
These are used to change the settings of
the setting items enclosed in the frame at the bottom of
the time code display.
To change a setting, keep pressing the corresponding
function button (
to
) until the desired
numerical value appears; alternatively, press the
corresponding function button to highlight the setting of
the setting item, and
then turn the ADJUST dial until
the desired numerical value is obtained.
F6
F1
F6
F1
F6
F1
SHIFT