Sanyo 26KHHS72R Service Manual - Page 31
Major Component Specifications, Indoor Unit
View all Sanyo 26KHHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
1-2 Major Component Specifications 1. Specifications (A) Indoor Unit MODEL No. XH2672R Source 230 - 208 VAC / 1 phase / 60 Hz Remote controller (Option) Wired or Wireless (See Unit Specification) Controller P. C. B Ass'y CR - TH2672 Control circuit fuse 250 VAC, 5 A Fan (Number ... diameter) in. (mm) Turbo (1...17-7/16 (443)) Fan motor Model SFG6X - 41D6P Source 230 - 208 V / 1 phase / 60 Hz No. of pole ... r.p.m. (230 V, High) rpm 6 ... 464 Nominal output W 40 Coil resistance Ω BRW - WHT : 170.3 , ORG - YEL : 43.2 (Ambient temperature 68 °F) WHT - VLT : 18.1 , WHT - PNK : 83.5 VLT - ORG : 43.2 , YEL - BLK : 60.2 Safety device Operating temperature Open °F 266 ± 14.4 Close °F 174.2 ± 27 Run capacitor VAC, µF 440 V , 4.5 µF 1 Heat exchanger Coil Aluminum plate fin / Copper tube Rows ... Fins per inch 2 ... 14.9 Face area ft.2 (m2) 3.69 (0.343) Panel Model No. Auto louver motor PNR - XH2442 2 MT8 - 3C Auto louver motor ... Rated V, W, rpm 240 VAC , 3 W , 3 rpm Coil resistance (Ambient temperature 77 °F) Ω 16.430 Ω ± 8 % DATA SUBJECT TO CHANGE WITHOUT NOTICE 3 4 5 6 SM831148 I-27