Sanyo 26KHHS72R Service Manual - Page 44
Heater Element Aux. Heater
![]() |
View all Sanyo 26KHHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
1-2 Major Component Specifications 1. Specifications (A) Indoor Unit MODEL No. KHH2672R Source 230 - 208 V / 1 phase / 60 Hz Remote controller (Option) Wired or Wireless (See Unit Specification) Controller P. C. B Ass'y CR - TH2672 Control circuit fuse 250 V, 5 A Fan Cross-flow Number ... Dia. and length in. (mm) 1 ... O.D. 4-1/3 (110), L39 (990) Fan motor Model UF4Q - 31A6P Source 230 - 208 V / 1 phase / 60 Hz No. of pole ... r.p.m. (230 V, High) rpm 4 ... 1,277 Nominal output W 30 Coil resistance (Ambient temperature 68 °F) Ω BRW - WHT : 197.2 , ORG - YEL : 59.1 WHT - VLT : 41.4 , YEL - PNK : 48.8 VLT - ORG : 22.2 , Safety device Operating temperature Open °F 248 ± 9 1 Run capacitor Close °F VAC, µF 171 ± 27 440 V , 1.8 µF Heater Element (Aux. Heater) Model AH - KH2412 Input (230 / 208 V) Protective thermostat 2 Thermo fuse Heat exchanger KW 1.8 / 1.5 OFF 140 ± 5°F, ON 113 ± 9°F Cut - off 370 + 2, - 5°F, 277V - 15A Coil Aluminum plate fin / Copper tube Rows ... 3 ... 12.7 Face area ft.2 (m2) 2.57 (0.24) Louver Motor 3 Model Rating M2EA24ZA01 208 to 230 V, 60 Hz No. of pole ... rpm 8 ... 3 Output W 2.5 Coil resistance (Ambient temperature 68 °F) kΩ 16.45 ± 8 % DATA SUBJECT TO CHANGE WITHOUT NOTICE 4 5 6 SM831148 I-40