Sanyo 26KHHS72R Service Manual - Page 51
Other Component Specifications, Indoor Unit
View all Sanyo 26KHHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
1-3 Other Component Specifications 1. Specifications (A) Indoor Unit MODEL No. XH2672R Power Transformer ATR - IIK224A Rated Primary 220 VAC, 60 Hz Secondary BRN - BRN : 14 V, 0.45 A, RED - RED : 14 V, 0.3 A Capacity - Coil resistance Ω (Ambient temprature 77 °F) WHT - WHT : 61.0 , RED - RED : 1.37 BRN - BRN : 0.97 , ORG - ORG : 3.16 Thermistor cut off temperature °F 277 Thermistor (Coil sensor) : TH2, 3 PBC - 41E - S14 Coil resistance kΩ 14 °F : 23.7 , 41 °F : 12.1 23 °F : 18.8 , 50 °F : 9.7 32 °F : 15.0 , 59 °F : 8.0 Thermistor (Room sensor) : TH1 KTEC - 35 - S6 Coil resistance kΩ 32 °F : 16.5 , 104 °F : 2.7 41 °F : 12.8 , 113 °F : 2.2 50 °F : 10.0 , 122 °F : 1.8 68 °F : 6.3 , 131 °F : 1.5 86 °F : 4.0 , Drain pump PJV - 1428AU Rated Float switch 230 / 208 VAC, 12.5 W FS - 0218 - 102 1 MAX Rated (Contact rated) 50 W, DC 5V, 0.1 mA Synchronized Motor MT8 - 3C 2 3 4 5 6 SM831148 I-47