Sanyo 26KHHS72R Service Manual - Page 57
MODEL No, THH2672R, Power Transformer, Thermistor Coil sensor, Thermistor Room or coil sensor
View all Sanyo 26KHHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
1-3 Other Component Specifications 1. Specifications (A) Indoor Unit MODEL No. Power Transformer Rated Primary Secondary Capacity Coil resistance (Ambient temprature 77 °F) Ω Thermistor cut off temperature °F Thermistor (Coil sensor) Coil resistance kΩ Thermistor (Room or coil sensor) Coil resistance kΩ Synchronized Motor THH2672R ATR - IIK244B AC 220 V, 60 Hz BRN - BRN : 14 V / 0.55 A, RED - RED : 14 V / 0.3 A - WHT - WHT : 48.0 , RED - RED : 0.89 BRN - BRN : 0.45 , ORG - ORG : 2.05 277 PBC - 41E - S14 14 °F : 23.7 23 °F : 18.8 32 °F : 15.0 41 °F : 12.1 50 °F : 9.7 , 59 °F : 8.0 , 68 °F : 6.5 , 86 °F : 4.4 , 104 °F : 3.1 , 113 °F : 2.6 PBC - 41E - S14 32 °F : 16.5 41 °F : 12.8 50 °F : 10.0 68 °F : 6.3 86 °F : 4.0 , 104 °F : 2.7 , 113 °F : 2.2 , 122 °F : 1.8 , 131 °F : 1.5 , MT8 - 3C 1 DATA SUBJECT TO CHANGE WITHOUT NOTICE 2 3 4 5 6 SM831148 I-53