Sanyo 26KHHS72R Service Manual - Page 32
Controller P. C. B Ass'y
![]() |
View all Sanyo 26KHHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
1-2 Major Component Specifications 1. Specifications (A) Indoor Unit MODEL No. XH3672R Source 230 - 208 VAC / 1 phase / 60 Hz Remote controller (Option) Wired or Wireless (See Unit Specification) Controller P. C. B Ass'y CR - TH2672 Control circuit fuse 250 VAC, 5 A Fan (Number ... diameter) in. (mm) Turbo (1...17-7/16 (443)) Fan motor Model SFG6X - 81A6P Source 230 - 208 V / 1 phase / 60 Hz No. of pole ... r.p.m. (230 V, High) rpm 6 ... 467 Nominal output W 60 Coil resistance Ω BRW - WHT : 75.1 , ORG - YEL : 27.4 (Ambient temperature 68 °F) WHT - VLT : 6.7 , VLT - PNK : 42.7 VLT - ORG : 20.6 , YEL - BLK : 58.0 Safety device Operating temperature Open °F 266 ± 14.4 Close °F 174.2 ± 27 1 Run capacitor Heat exchanger VAC, µF 440 V , 5 µF Coil Aluminum plate fin / Copper tube Rows ... Fins per inch 2 ... 14.9 Face area ft.2 (m2) 8.20 (0.762) Panel 2 Model No. Auto louver motor PNR - XH3642 MT8 - 3C Auto louver motor ... Rated V, W, rpm 240 VAC , 3 W , 3 rpm Coil resistance (Ambient temperature 77 °F) Ω 16.430 Ω ± 8 % DATA SUBJECT TO CHANGE WITHOUT NOTICE 3 4 5 6 SM831148 I-28
![](/manual_guide/products/sanyo-26khhs72r-service-manual-8912f5e/32.png)