Sanyo 26KHHS72R Service Manual - Page 37
Heater Ass'y Aux. Heater
View all Sanyo 26KHHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
1-2 Major Component Specifications 1. Specifications (A) Indoor Unit MODEL No. THH2672R Source 230 - 208 V / 1 phase / 60 Hz Remote controller (Option) Wired or Wireless (See Unit Specification) Controller P. C. B Ass'y CR - TH2672 Control circuit fuse 250 V, 5 A Fan (Number ... diameter) in. (mm) Centrifugal (4 ... 5-1/8(130)) Fan motor Model SR4X - 51A6P Source 230 - 208 V / 1 phase / 60 Hz No. of pole ... r.p.m. (230 V, High) rpm 1,187 Nominal output W 31 Coil resistance (Ambient temperature 68 °F) Ω BRW - WHT : 111.0 , ORG - YEL : 16.7 WHT - VLT : 35.4 , BLK - PNK : 23.9 VLT - ORG : 13.4 , YEL - BLK : 136.6 Safety device Operating temperature Open °F 266 ± 14.4 Close °F 174.2 ± 27 Run capacitor Heater Ass'y (Aux. Heater) VAC, µF 440 V , 1.5 µF 1 Model AH - 1.8THS2432 Input (230 / 208 V) KW 1.8 / 1.45 Protective thermostat CS- 12AL OFF 122 ± 6°F, ON 104 ± 10°F Thermo fuse Heat exchanger Coil SF96U Cut - off 205 ± 4°F 2 Aluminum plate fin / Copper tube Rows ... Fins per inch 3 ... 14.9 Face area ft.2 (m2) 1.81 (0.168) Auto louver motor Model No. MT8 - 3C Auto louver motor ... Rated V, W, rpm 240 VAC , 3 W , 3 rpm 3 Coil resistance (Ambient temperature 77 °F) Ω 16,430 Ω ± 8 % DATA SUBJECT TO CHANGE WITHOUT NOTICE 4 5 6 SM831148 I-33