Sanyo 26KHHS72R Service Manual - Page 65
CH3072R, C3072R, CH3672R, C3672R
![]() |
View all Sanyo 26KHHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
1-3 Other Component Specifications 1. Specifications (B) Outdoor Unit MODEL No. Thermistor (Coil sensor) : TH2 to 5 Coil resistance kΩ Thermistor (Comp. discharge gas sensor) : TH6 Coil resistance kΩ Solenoid coil or 4 way valve 4 way valve Solenoid coil Electric expansion valve (MOV) Valve Coil CH3072R, C3072R, CH3672R, C3672R 14 °F : 23.7 23 °F : 18.8 32 °F : 15.0 41 °F : 12.1 , 50 °F : 9.7 , 68 °F : 6.5 , 86 °F : 4.4 , 104 °F : 3.1 113 °F : 2.6 140 °F : 13.8 158 °F : 9.7 167 °F : 8.2 176 °F : 7.0 185 °F : 5.9 , 194 °F : 5.1 , 212 °F : 3.8 , 230 °F : 2.8 , 248 °F : 2.2 , 266 °F : 1.7 STF - 02U2G STF - 01AQ503UA1 (Heat pump models only) UKV - 18D13 UKV - U013E DATA SUBJECT TO CHANGE WITHOUT NOTICE 1 2 3 4 5 6 SM831148 I-61
![](/manual_guide/products/sanyo-26khhs72r-service-manual-8912f5e/65.png)
1
I-61
SM831148
1. Specifications
1-3
Other Component Specifications
(B) Outdoor Unit
MODEL No.
CH3072R, C3072R, CH3672R, C3672R
Thermistor (Coil sensor) : TH2 to 5
Coil resistance
k
Ω
14
°
F : 23.7
,
50
°
F : 9.7
23
°
F : 18.8
,
68
°
F : 6.5
32
°
F : 15.0
,
86
°
F : 4.4
41
°
F : 12.1
,
104
°
F : 3.1
113
°
F : 2.6
Thermistor (Comp. discharge gas sensor) : TH6
Coil resistance
k
Ω
140
°
F : 13.8
,
194
°
F : 5.1
158
°
F:
9.7
,
212
°
F : 3.8
167
°
F:
8.2
,
230
°
F : 2.8
176
°
F:
7.0
,
248
°
F : 2.2
185
°
F:
5.9
,
266
°
F : 1.7
Solenoid coil or 4 way valve
4 way valve
STF - 02U2G
Solenoid coil
STF - 01AQ503UA1 (Heat pump models only)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Electric expansion valve (MOV)
Valve
UKV - 18D13
Coil
UKV - U013E