Sanyo 26KHHS72R Service Manual - Page 45

Major Component Specifications, Outdoor Unit

Page 45 highlights

1-2 Major Component Specifications (B) Outdoor Unit MODEL No. Source Controller P.C.B. Ass'y Control circuit fuse (on the P.C.B."FIL-CH4872R") Compressor Model....number Nominal output W Compressor oil cc Coil resistance Ω (Ambient temperature 25 °C) Safety control Microprocessor safety devices Overload protector (Operating temperature) Crank case heater Refrigerant amount at shipment High pressure switch Set pressure Fan Number.. diameter Air circulation (Hi) Fan speeds (Max.) Fan motor Model No. Source No. of pole Nominal output Coil resistance (Ambient temperature 20 °C) Safety device Operating temperature Run capacitor Heat exchanger Coil Rows....fin pitch Face area Open °F (°C) Close °F (°C) lbs. (kg) OFF PSi ON PSi mm m3/h W Ω Open Close VAC, °F (°C) °F (°C) µF mm m2 1. Specifications CH2672R 208 - 230 V / 1 phase / 60 Hz CR-CH4872R (Microprocessor) 280 V, 25 A C - R : 0.665 C - S : 0.665 C-7RVN153H0V 1,500 650 R - S : 0.665 Compressor Discharge Gas temperature control Comressor current detection circuit 230 (110) 203 (95) - R410A - 4.19 (1.9) - 1 600 456 Propeller 1.... ø460 3,000 2 ~800 rpm (Inverter drive control) DAJ12-95B61A (-C, -CR) DC340 V / 3 phase 8 90 3 RED - WHT : 30.5 WHT - BLK : 30.5 BLK - RED : 30.5 284 (140) - - 4 Aluminium plate fin / Copper tube 1.. ..1.6 0.675 5 6 SM831148 I-41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

1
I-41
SM831148
1. Specifications
1-2
Major Component Specifications
(B)
Outdoor Unit
MODEL No.
Source
Controller P.C.B. Ass'y
Control circuit fuse (on the P.C.B.
FIL-CH4872R
)
Compressor
Model
....
number
Nominal output
W
Compressor oil
cc
Coil resistance
C
R : 0.665
R
S
: 0.665
(Ambient temperature 25
°
C)
C
S
: 0.665
Safety control
Microprocessor safety devices
Overload protector
(Operating temperature)
Open
Close
Crank case heater
Refrigerant amount at shipment
lbs. (kg)
High pressure switch
Fan
Number.. diameter
mm
Air circulation (Hi)
m
3
/h
Fan speeds (Max.)
Fan motor
Model No.
Source
No. of pole
Nominal output
W
Coil resistance
RED
WHT
:
30.5
WHT
BLK
:
30.5
(Ambient temperature 20
°
C)
BLK
RED
:
30.5
Safety device
Operating temperature
Open
°
F (
°
C)
Close
°
F (
°
C)
Run capacitor
VAC,
μF
Heat exchanger
Coil
Rows
....
fin pitch
mm
Face area
m
2
CR-CH4872R (Microprocessor)
C-7RVN153H0V
280 V, 25 A
CH2672R
208 - 230 V / 1 phase / 60 Hz
PSi
Set pressure
OFF
DAJ12-95B61A (-C, -CR)
3,000
1
....
ø
460
~800 rpm (Inverter drive control)
R410A - 4.19 (1.9)
600
456
1,500
650
Compressor Discharge Gas temperature control
Comressor current detection circuit
230 (110)
203 (95)
DC340 V / 3 phase
Propeller
284 (140)
8
90
1
....
1.6
PSi
ON
0.675
Aluminium plate fin / Copper tube
°
F (
°
C)
°
F (
°