Sanyo 26KHHS72R Service Manual - Page 38
Heat exchanger
View all Sanyo 26KHHS72R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
1-2 Major Component Specifications 1. Specifications (A) Indoor Unit MODEL No. THH3672R Source 230 - 208 V / 1 phase / 60 Hz Remote controller (Option) Wired or Wireless (See Unit Specification) Controller P. C. B Ass'y CR - TH2672 Control circuit fuse 250 V, 5 A Fan (Number ... diameter) in. (mm) Centrifugal (4 ... 5-29/32(150)) Fan motor Model KFG4X - 101C6P Source 230 - 208 V / 1 phase / 60 Hz No. of pole ... r.p.m. (230 V, High) rpm 4 ... 1,015 Nominal output W 100 Coil resistance (Ambient temperature 68 °F) Ω BRW - WHT : 61.05 , ORG - YEL : 13.23 WHT - VLT : 9.955 , YEL - BLK : 19.25 VLT - ORG : 9.576 , BLK - PNK : 10.81 Safety device Operating temperature Open °F 266 ± 14.4 Close °F 174.2 ± 27 1 Run capacitor Heater Ass'y (Aux. Heater) VAC, µF 440 V , 4 µF Model AH - 2.4THS3632 Input (230 / 208 V) KW 2.4 / 1.94 Protective thermostat CS- 12AL OFF 122 ± 6°F, ON 104 ± 10°F Thermo fuse 2 Heat exchanger Coil SF96U Cut - off 205 ± 4°F Aluminum plate fin / Copper tube Rows ... Fins per inch 3 ... 14.9 Face area ft.2 (m2) 3.51 (0.326) Auto louver motor Model No. 3 Auto louver motor ... Rated V, W, rpm Coil resistance (Ambient temperature 77 °F) Ω MT8 - 3C 240 VAC , 3 W , 3 rpm 16,430 Ω ± 8 % DATA SUBJECT TO CHANGE WITHOUT NOTICE 4 5 6 SM831148 I-34