PLC-XD2200/2600 Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command "CF_FSYNC_%1"[CR] "0000~0031 Directly select Fine Sync setting value %1 "UP Current Fine Sync setting value + 1 "DN Current Fine Sync setting value - 1 Details Set Fine Sync value of PC signal Projector does not save the value set with this command so that it resets when projector turning into Standby status or ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.5.2 CF_TDOTS Command Command "CF_TDOTS_%1"[CR] "mmmm~nnnn" --- Directly select Total Dots setting value "mmmm" shows minimum value, it is current Display Dots Horizontal value + %1 Position value. "nnnn" shows maximum value, which is not over 140MHz. "UP Current Total Dots setting value + 1 "DN Current Total Dots setting value - 1 Details Set Total Dots of PC signal Projector does not save the value set with this command so that it resets when projector turning into Standby status or ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.5.3 CF_CLAMP Command Command "CF_CLAMP_%1"[CR] "mmmm~nnnn" ---- Directly select Clamp setting value "mmmm" shows minimum value, fixed-value "0001". %1 "nnnn" shows maximum value: it depends on input signal. "UP Current Clamp setting value + 1 "DN Current Clamp setting value - 1 Details Set Clamp value of PC signal Projector does not save the value set with this command so that it resets when projector turning into Standby status or ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 22 / 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

PLC-XD2200/2600
Expand Serial Command Functional Specifications
22 / 71
8.5
PC Adjust Control Command
8.5.1
CF_FSYNC Command
Command
“CF_FSYNC_%1”[CR]
%1
“0000~0031” --------------- Directly select Fine Sync setting value
“UP” -------------------------- Current Fine Sync setting value + 1
“DN” -------------------------- Current Fine Sync setting value - 1
Details
Set Fine Sync value of PC signal
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]
8.5.2
CF_TDOTS Command
Command
“CF_TDOTS_%1”[CR]
%1
“mmmm~nnnn” --- Directly select Total Dots setting value
“mmmm” shows minimum value, it is current Display Dots Horizontal value +
Position value
.
“nnnn” shows maximum value, which is not over 140MHz.
“UP” -------------- Current Total Dots setting value + 1
“DN” -------------- Current Total Dots setting value - 1
Details
Set Total Dots of PC signal
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]
8.5.3
CF_CLAMP Command
Command
“CF_CLAMP_%1”[CR]
%1
“mmmm~nnnn” ---- Directly select Clamp setting value
“mmmm” shows minimum value, fixed-value “0001”.
“nnnn” shows maximum value: it depends on input signal.
“UP” ------------------ Current Clamp setting value + 1
“DN” ------------------ Current Clamp setting value – 1
Details
Set Clamp value of PC signal
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]