Sanyo PLC-XD2200 RS232C Expand - Page 58
Lamp Status Read Command, CR_LAMPREPL Command, CR_LAMPH Command, CR_LAMPCORRESPH Command,
UPC - 086483078644
View all Sanyo PLC-XD2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
PLC-XD2200/2600 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL"[CR] Details Get information of Lamp Replacement time Acceptable "000_%1"[CR] "1Y Over lamp replacement time "1N Within lamp replacement time Response %1 "1" means the number of lamps. (1 lamp model→ "1") "Y"/"N" means if it has reached its replacement time or not. e.g. "1Y projector is 1 lamp model and Lamp is over its replacement time Unacceptable "Error Code"[CR] 9.9.2 CR_LAMPH Command Command "CR_LAMPH"[CR] Details Get total running time of lamp by hour (h) *Actual running time, not corresponding value Acceptable "000_%1"[CR] Response %1 "00000"~"99999" Unacceptable "Error Code"[CR] 9.9.3 CR_LAMPCORRESPH Command Command "CR_LAMPCORRESPH"[CR] Details Get total running time of lamp by hour (h) * Corresponding value, not actual running time Acceptable "000_%1"[CR] Response %1 "00000"~"99999" Unacceptable "Error Code"[CR] 9.9.4 CR_LAMPMODE Command Command "CR_LAMPMODE"[CR] Details Get setting status of Lamp Mode Acceptable "000_%1"[CR] "HIGH Lamp Mode is High Response %1 "NORMAL Lamp Mode is Normal "ECO Lamp Mode is Eco Unacceptable "Error Code"[CR] 58 / 71