Sanyo PLC-XD2200 RS232C Expand - Page 69

CR_TEMPWARN Command

Page 69 highlights

PLC-XD2200/2600 Expand Serial Command Functional Specifications 9.12.5 CR_TEMPWARN Command Command "CR_TEMPWARN"[CR] Details Get the temperature inside a projector and its condition if it is abnormal temperature or close to abnormal temperature If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable "000_%a_%b_%c"[CR] %a Sensor 1 status %b Sensor 2 status %c Sensor 3 status "W" ---- Approach or reach abnormal temperature (dangerous temperature) "S" ---- Far from abnormal temperature (safe temperature) "N" ---- Sensor detects no abnormal temperature Response %a %b %c [Example] "S_W_S"[CR] means Sensor 1 detects safe temperature, Sensor 2 detects abnormal temperature and Sensor 3 detects safe temperature Note) When the temperature difference between Sensor 1 and 3 reaches specific value, some of the models detect it as Abnormal temperature. In this case, the 3rd data shows if the temperature difference between Sensor 1 and 3 is dangerous state or not. The 3rd data means temperature abnormality due to Sensor 3 When abnormal temperature is not detected by sensor, "N" (No connection with temperature abnormality) is returned. Unacceptable "Error Code" [CR] 69 / 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

PLC-XD2200/2600
Expand Serial Command Functional Specifications
69 / 71
9.12.5 CR_TEMPWARN Command
Command
“CR_TEMPWARN”[CR]
Details
Get the temperature inside a projector and its condition if it is abnormal
temperature or close to abnormal temperature
If there are several sensors installed, it is possible to get information from all the
sensors at once.
Response
Acceptable
“000_%a_%b_%c”[CR]
%a
%b
%c
%a -------------------- Sensor 1 status
%b -------------------- Sensor 2 status
%c -------------------- Sensor 3 status
“W” ---- Approach or reach abnormal temperature
(dangerous temperature)
“S” ---- Far from abnormal temperature (safe temperature)
“N” ---- Sensor detects no abnormal temperature
[Example]
“S_W_S”[CR] means Sensor 1 detects safe temperature, Sensor
2 detects abnormal temperature and Sensor 3 detects safe
temperature
Note) When the temperature difference between Sensor 1 and 3
reaches specific value, some of the models detect it as Abnormal
temperature. In this case, the 3rd data shows if the temperature
difference between Sensor 1 and 3 is dangerous state or not. The
3rd data means temperature abnormality due to Sensor 3
When abnormal temperature is not detected by sensor, “N” (No
connection with temperature abnormality) is returned.
Unacceptable
“Error Code” [CR]