Sanyo PLC-XD2200 RS232C Expand - Page 71
CR_TEMPFAIL Command
UPC - 086483078644
View all Sanyo PLC-XD2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
PLC-XD2200/2600 Expand Serial Command Functional Specifications 9.12.7 CR_TEMPFAIL Command Command "CR_TEMPFAIL"[CR] Details Get the temperature inside a projector when abnormal temperature occurs. If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable "000_%a_%b_%c"[CR] %a Sensor 1 temp. (External temp.) %b Sensor 2 temp. (Internal temp.1) %c Sensor 3 temp. (Internal temp.2) [Example] "_31.5F"[CR] "_" indicates a space. When the temperature sinks to -, the first character is "-" like "-05.5F"[CR] The last character means the sensor's status if it reaches abnormal temperature %a Response %b Exceeding critical temp F" %c Temp. is safe S" Sensor detects no critical temp N" The example shows that sensor 1 indicates 31.5 degrees and the temperature is abnormal. When the temperature is safe, all data are represented as "□000S". When the projector is reset, "□000S" is set, and every time abnormal temperature occurs, it renews the data and returns it. In short, it only returns the renewed data of the latest abnormal temperature and the previous data is deleted. Unacceptable "Error Code" [CR] 71 / 71