Sanyo PLC-XD2200 RS232C Expand - Page 46
Image Status Read Command, CR_BRIGHT Command, CR_CONT Command, CR_COLOR Command, CR_TINT Command,
UPC - 086483078644
View all Sanyo PLC-XD2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
PLC-XD2200/2600 Expand Serial Command Functional Specifications 9.4 Image Status Read Command 9.4.1 CR_BRIGHT Command Command "CR_BRIGHT"[CR] Details Get Brightness value of user control Acceptable "000_ "[CR] Response %a "000"~"063" Unacceptable "Error Code"[CR] 9.4.2 CR_CONT Command Command "CR_CONT"[CR] Details Get Contrast value of user control Acceptable "000_ "[CR] Response %a "000"~"063" Unacceptable "Error Code"[CR] 9.4.3 CR_COLOR Command Command "CR_COLOR"[CR] Details Get Color value of user control Acceptable "000_%a"[CR] Response %a "000"~"063" Unacceptable "Error Code"[CR] 9.4.4 CR_TINT Command Command "CR_TINT"[CR] Details Get Tint value of user control Acceptable "000_%a"[CR] Response %a "000"~"063" Unacceptable "Error Code"[CR] 9.4.5 CR_SHARP Command Command "CR_SHARP"[CR] Details Get Sharpness value of user control Acceptable "000_%a"[CR] Response %a "000"~"015" Unacceptable "Error Code"[CR] 9.4.6 CR_GAMMA Command Command "CR_GAMMA"[CR] Details Get Gamma value of user control Response Acceptable %a "000_%a"[CR] "000"~"015" 46 / 71