Sanyo PLC-XD2200 RS232C Expand - Page 66
CR_DELAYCTRL Command, 11.26 CR_FILH Command, 11.27 CR_CCAPTIONDISP Command, 11.28
UPC - 086483078644
View all Sanyo PLC-XD2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
PLC-XD2200/2600 Expand Serial Command Functional Specifications 9.11.25 CR_DELAYCTRL Command Command "CR_DELAYCTRL"[CR] Details Get setting status of Video delay control Acceptable "000_%1"[CR] Response %1 "ON Video delay control is active "OFF Video delay control is inactive Unacceptable "Error Code"[CR] 9.11.26 CR_FILH Command Command "CR_FILH"[CR] Details Get Filter used time Acceptable "000_%1"[CR] Response %1 "00000"~"99999 0 hour to 99999 hours Unacceptable "Error Code"[CR] 9.11.27 CR_CCAPTIONDISP Command Command "CR_CCAPTIONDISP"[CR] Details Get selected channel of Closed caption Acceptable "000_%a"[CR] Response "OFF" --------- Off "CC1" --------- CC1 is selected a "CC2" --------- CC2 is selected "CC3"--------- CC3 is selected "CC4" --------- CC4 is selected Unacceptable "Error Code"[CR] 9.11.28 CR_CCAPTIONCOLOR Command Command "CR_CCAPTIONCOLOR_%1"[CR] Details Get selected color of Closed caption Acceptable "000"[CR] Response %a "COLOR" ------- Color is selected "WHITE" -------- White is selected Unacceptable "Error Code"[CR] 9.11.29 CR_FILREPL Command Command "CR_FILREPL"[CR] Details Get the information of Filter replacement time Acceptable "000_%1"[CR] Response %1 "1Y Over filter replacement time "1N Within filter replacement time Unacceptable "Error Code"[CR] 66 / 71