PLC-XD2200/2600 Expand Serial Command Functional Specifications 9.11.15 CR_PTIMEMODE Command Command "CR_PTIMEMODE"[CR] Details Get operation mode of P-timer. Acceptable "000_%a"[CR] Response %a "COUNTUP Count up is selected "COUNTDN Count down is selected. Unacceptable "Error code"[CR] 9.11.16 CR_PTIMER Command Command "CR_PTIMER"[CR] Details Get current status of P-timer Acceptable "000_%a"[CR] "ON P-timer is in execution Response %a "STOP P-timer is paused "OFF P-timer is inactive Unacceptable "Error code"[CR] 9.11.17 CR_PTIME Command Command "CR_PTIME"[CR] Details Get setting status of Countdown timer. Acceptable "000_%a"[CR] Response %a "001"~"180 1~180 minutes Unacceptable "Error code"[CR] 9.11.18 CR_RCODE Command Command "CR_RCODE"[CR] Details Get selected Remote Control Code Acceptable "000_%a"[CR] Response %a "001 Code1 is selected "002 Code2 is selected Unacceptable "Error Code" [CR] 9.11.19 CR_SECURITY Command Command "CR_SECURITY" [CR] Details Get Security Mode setting status Acceptable "000_%1[CR] Response %1 "ON PJ Lock setting on Menu is ON-1 or ON-2 "OFF PJ Lock setting on Menu is OFF Unacceptable "Error Code" [CR] 64 / 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

PLC-XD2200/2600
Expand Serial Command Functional Specifications
64 / 71
9.11.15 CR_PTIMEMODE Command
Command
“CR_PTIMEMODE”[CR]
Details
Get operation mode of P-timer.
Response
Acceptable
“000_%a”[CR]
%a
“COUNTUP” ---------------- Count up is selected
“COUNTDN” ---------------- Count down is selected.
Unacceptable
“Error code”[CR]
9.11.16 CR_PTIMER Command
Command
“CR_PTIMER”[CR]
Details
Get current status of P-timer
Response
Acceptable
“000_%a”[CR]
%a
“ON” ------------------------ P-timer is in execution
“STOP” --------------------- P-timer is paused
“OFF” ----------------------- P-timer is inactive
Unacceptable
“Error code”[CR]
9.11.17 CR_PTIME Command
Command
“CR_PTIME”[CR]
Details
Get setting status of Countdown timer.
Response
Acceptable
“000_%a”[CR]
%a
“001”~“180”
------------1~180 minutes
Unacceptable
“Error code”[CR]
9.11.18 CR_RCODE Command
Command
“CR_RCODE”[CR]
Details
Get selected Remote Control Code
Response
Acceptable
“000_%a”[CR]
%a
“001” --------------------------- Code1 is selected
“002” --------------------------- Code2 is selected
Unacceptable
“Error Code” [CR]
9.11.19 CR_SECURITY Command
Command
“CR_SECURITY” [CR]
Details
Get Security Mode setting status
Response
Acceptable
“000_%1[CR]
%1
“ON” ------------- PJ Lock setting on Menu is ON-1 or ON-2
“OFF” ------------PJ Lock setting on Menu is OFF
Unacceptable
“Error Code” [CR]