The following intervals apply to normal operating conditions only. If your daily work
View all Stihl FS 560 C-EM manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
The following intervals apply to normal operating conditions only. If your daily working time is longer or operating conditions are difficult (very dusty work area, etc.), shorten the specified intervals accordingly. Spacer Check X Replace2) X Exhaust port Decoke after first 139 hours of operation, then every 150 hours of operation All accessible screws and nuts (not adjusting screws) 3) Retighten Check4) X Antivibration elements Replace2) Visual inspection X X Cutting attachment Replace Check tightness X X Metal cutting attachment Sharpen X Safety labels Replace 1) Only if there is a noticeable loss of engine power 2) STIHL recommends that this work be done by a STIHL servicing dealer 3) Tighten down the muffler mounting screws firmly after first 10 to 20 hours of operation. 4) see chapter "Inspection and Maintenance by Dealer", section "Antvibration elements" before starting work after finishing work or daily after each refueling stop weekly monthly every 12 months if problem if damaged if required English X X X X X X X X FS 510 C-M, FS 560 C-M 49