Sub-Zero 427R Wine Storage Installation Instructions - Page 45
Model WS-30 Installation, Framed Panel, Framed Panel Specifications
View all Sub-Zero 427R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Model WS-30 Installation 45 subzero.com Framed Panel RAISED PANEL With some door panel designs, you may have to rout, recess or use optional extended handles to allow for finger clearance. This is particularly true if your unit has raised panels greater than 1/4" (6) total thickness. Check the location of offset when you're using specific routing for the grip area only. Refer to the Sub-Zero design guide for a full-scale template of the standard full-length handle and panel. Use this template to lay out your panel design for finger clearance when a standard full-length handle is used. IMPORTANT NOTE: The weight of the framed panel must not exceed 75 lbs (34 kg). A solid panel cannot be installed over the glass door, as this may cause moisture to form behind the panel. Framed Panel Specifications A A A H A W Model WS-30 DOOR Door Panel WINDOW Cut-Out Location W 293/4" (756) W 231/2" (597) H 699/16" (1767) H 635/16" (1608) A 31/8" (79)