periodic
View all TP-Link T1500G-8T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 199 highlights
Repeat this command to create multiple absolute time-ranges. Up to 7 absolute time-ranges can be created in one Time-range, and their union is the Absolute Time-range. If no absolute time range is configured, the absolute time range takes effect from January 1, 2000 00:00 to December 31, 2099 24:00. To delete the corresponding absolute time-range, please use no absolute command. Syntax absolute from start-date to end-date no absolute [ index ] Parameter start-date -- The start date in Absolute Mode, in the format of MM/DD/YYYY-HH:MM. end-date -- The end date in Absolute Mode, in the format of MM/DD/YYYY-HH:MM. index -- Specify the index of the absolute time-range to delete. If not specified, all absolute time-ranges will be deleted. Command Mode Power Time-range Configuration Mode Privilege Requirement Only Admin, Operator and Power User level users have access to these commands. Example Create an absolute mode time-range for the PoE of the switch and specify the date extending from 08:00 on May 5th, 2012 to 22:00 on Oct. 5th, 2012: T1500G-10MPS(config)# power time-range tRange1 T1500G-10MPS(config-time-range)# absolute from 05/05/2012-08:00 to 10/05/2012-22:00 22.5 periodic Description The periodic command is used to create a periodic mode time-range for the PoE time-range of the switch. The periodic time-range reccurs every week. 186