Thermador UCVP36XS Installation Instructions - Page 12

Accessories

Page 12 highlights

A C C E S S O R I E S (purchase separately) Flexible Blower Thermador Model VTD600P Inline and Remote Blowers Thermador Models VTI610, VTR630, VTI1010, VTR1030, VTR1330 MODEL UCVRECIRC UCVFILTER (replacement ilter) CVTFRONT8 CVTFRONT6 CVTFRONT10 EXTNCE5 UCV30ST UCV36ST DESCRIPTION Non-Duct Recirculating Kit Used in applications where ducting is not feasible or available. Mount to toe kick or base of a cabinet and attach directly to VTD600P Flexible Blower using 8" (203 mm) round duct. Kit can be rotated so that the exhaust is not directly at your feet. Includes decorative cover plate. Rough-in Plate - 8" (203 mm) Round Use for applications where 8" (203 mm) round duct or elbow attaches to front of airbox (VTD600P inline blower installation). Rough-in Plate - 6" or 10" (152 mm or 254 mm) Round Use for applications where 6" or 10" (152 mm or 254 mm) round duct or elbow attaches to front of airbox (inline or remote blower installation). Extension Cable - 5-ft. (1.5 m) Used in applications where the electrical panel is remotely mounted. If blower discharge is down, electrical panel must be relocated. Extends electrical panel cable an additional 5-feet (1.5 m)with the ability to connect up to two extension cables. Gas Cooktop Seal Kit - 30-in. (762 mm), 36-in. (914 mm) Used to provide seal between gas cooktop and downdraft. Also includes cabinet hole cover plates. Two grilles are provided in the kit, you may only need one for your speciic installation. Rectangular Duct - 2-ft. (0.6 m) sections (1-7/8" x 19" /48 mm x 483 mm) Galvanized steel construction. 2-ft. (0.6 m) sections can be connected together. CVDUCT2 CVTRECT2 Rectangular Adapter for 1-7/8" x 19" (48 mm x 483 mm) Use to connect 1-7/8" x 19" (48 mm x 483 mm) rectangular duct directly to downdraft when using side, below or rear exhaust. MODEL DESCRIPTION 1-7/8" X 19" (48 mm x 483 mm) to 8" (203 mm) Round Transition Rectangular to 8" (203 mm) round transition for left, right, below, or rear exhaust - using Model VTD600P Flex Blower. Can be attached to downdraft unit or rectangular duct (CVDUCT2). CVTSIDE8 CVTSIDE6 CVTSID10 2 1 B Connects to Hood C Connects to Remote or In-line Blower EXTNCB25W EXTNSET4 1-7/8" X 19" (48 mm x 483 mm) to 6" or 10" (152 mm or 254 mm) Round Transition Rectangular to 6" or 10" (152 mm or 254 mm) round transition for left, right, below, or rear exhaust using inline or remote blower. Can be attached to downdraft unit or rectangular duct (CVDUCT2). Extension Cable - 25-ft. (7.62 m) The remote or inline blower harness should be routed through the knockout and secured with a 3/4" (19 mm) strain relief. The 25 ft. Extension Cable can then be connected to the Adapter Cable included in EXTNSET4 Accessory Kit and then to the hood electrical panel. Extension Cable Connection Kit Cable connection kit containing (4) accessory cable adapters to connect a variety of blower and hood combinations. Page 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Page 12
ACCESSORIES
(purchase separately)
Flexible Blower
Thermador Model VTD600P
MODEL
DESCRIPTION
UCVRECIRC
UCVFILTER
(replacement ±lter)
Non-Duct Recirculating Kit
Used in applications where ducting is not
feasible or available. Mount to toe kick
or base of a cabinet and attach directly
to VTD600P Flexible Blower using 8”
(203 mm) round duct. Kit can be rotated
so that the exhaust is not directly at your
feet. Includes decorative cover plate.
CVTFRONT8
Rough-in Plate - 8” (203 mm) Round
Use for applications where 8” (203 mm)
round duct or elbow attaches to front
of airbox (VTD600P inline blower
installation).
CVTFRONT6
CVTFRONT10
Rough-in Plate - 6” or 10” (152 mm or
254 mm) Round
Use for applications where 6” or 10”
(152 mm or 254 mm) round duct or
elbow attaches to front of airbox (inline
or remote blower installation).
EXTNCE5
Extension Cable - 5-ft. (1.5 m)
Used in applications where the electrical
panel is remotely mounted. If blower
discharge is down, electrical panel
must be relocated. Extends electrical
panel cable an additional 5-feet (1.5 m)-
with the ability to connect up to two
extension cables.
UCV30ST
UCV36ST
Gas Cooktop Seal Kit - 30-in. (762 mm),
36-in. (914 mm)
Used to provide seal between gas
cooktop and downdraft. Also includes
cabinet hole cover plates. Two grilles are
provided in the kit, you may only need
one for your speci²c installation.
CVDUCT2
Rectangular Duct - 2-ft. (0.6 m) sections
(1-7/8” x 19” /48 mm x 483 mm)
Galvanized steel construction.
2-ft. (0.6 m) sections can be connected
together.
CVTRECT2
Rectangular Adapter for 1-7/8” x 19”
(48 mm x 483 mm)
Use to connect 1-7/8” x 19” (48 mm x
483 mm) rectangular duct directly to
downdraft when using side, below or
rear exhaust.
MODEL
DESCRIPTION
CVTSIDE8
1-7/8” X 19” (48 mm x 483 mm)
to 8” (203 mm) Round
Transition
Rectangular to 8” (203 mm) round
transition for left, right, below, or rear
exhaust - using Model VTD600P Flex
Blower. Can be attached to downdraft
unit or rectangular duct (CVDUCT2).
CVTSIDE6
CVTSID10
1-7/8” X 19” (48 mm x 483 mm) to 6” or
10” (152 mm or 254 mm) Round
Transition
Rectangular to 6” or 10” (152 mm or
254 mm) round transition for left, right,
below, or rear exhaust using inline or
remote blower. Can be attached to
downdraft unit or rectangular duct
(CVDUCT2).
B
Connects to Hood
C
Connects to Remote
or In-line Blower
EXTNCB25W
Extension Cable - 25-ft. (7.62 m)
The remote or inline blower harness
should be routed through the knockout
and secured with a 3/4” (19 mm) strain
relief. The 25 ft. Extension Cable can
then be connected to the Adapter Cable
included in EXTNSET4 Accessory Kit and
then to the hood electrical panel.
EXTNSET4
Extension Cable Connection Kit
Cable connection kit containing
(4) accessory cable adapters to
connect a variety of blower and hood
combinations.
Inline and Remote Blowers
Thermador Models VTI610, VTR630, VTI1010, VTR1030, VTR1330
1
2