Adaptec 2074700-R User Guide - Page 113

Table 10-8. Controller Settings

Page 113 highlights

ICP RAID Console Table 10-8. Controller Settings Parameter Cache Delayed Write BIOS BIOS Warning Level SETUP from Flash-RAM Display Supported BIOS Drives CD-ROM Boot Memory Test Halt on Firmware messages Immediate Hard Disk start Chn. SCSI-A Termination Chn. SCSI-A SCSI ID Chn. SCSI-B Termination Chn. SCSI-B SCSI ID Alternatives On Off On Off Enabled Disabled Removed All Messages Fatal Errors Disabled Enabled Off On 2 7 Disabled Enabled No test Standard Double scan Intensive Off On Off On Auto 0,1,2,3,4,5,6,7 Auto 0,1,2,3,4,5,6,7 Description ICP RAID cache (write and read cache) On ICP RAID cache (write and read cache) Off Write cache On Write cache Off BIOS enabled BIOS disabled, but + allowed BIOS and + disabled All ICP RAID BIOS warnings and errors are displayed Only fatal messages are displayed + not possible + allowed + not displayed at system boot level + displayed at system boot level The ICP RAID BIOS supports 2 drives The ICP RAID BIOS supports 7 drives Boot from CD-ROM disabled Boot from CD-ROM enabled No test at all Standard test Double scan test Intensive test (takes longer) Don't stop display of firmware messages during system boot Stop display of firmware messages during system boot when any error occurs Initiate hard disks one at a time Initiate all hard disks at the same time SCSI termination according to occupied connectors Possible SCSI IDs for the channel SCSI termination according to occupied connectors Possible SCSI IDs for the channel All information concerning physical, logical, array and host drives are stored twice (primary and secondary configuration data) on each hard disk. For example, the ICP RAID controller itself carries no configuration data of a specific disk array. For this reason Software Installation and User's Guide 113

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214

Software Installation and User’s Guide
113
ICP RAID Console
All information concerning physical, logical, array and host drives are stored twice
(primary and secondary configuration data)
on each hard disk. For example, the ICP
RAID controller itself carries no configuration data of a specific disk array. For this reason
Table 10-8. Controller Settings
Parameter
Alternatives
Description
Cache
On
ICP RAID cache (write and read cache) On
Off
ICP RAID cache (write and read cache) Off
Delayed Write
On
Write cache On
Off
Write cache Off
BIOS
Enabled
BIOS enabled
Disabled
BIOS disabled, but <Ctrl>+<G> allowed
Removed
BIOS and <Ctrl>+<G> disabled
BIOS Warning
Level
All Messages
All ICP RAID BIOS warnings and errors are displayed
Fatal Errors
Only fatal messages are displayed
SETUP from
Flash-RAM
Disabled
<Ctrl>+<G> not possible
Enabled
<Ctrl>+<G> allowed
Display
Off
<Ctrl>+<G> not displayed at system boot level
On
<Ctrl>+<G> displayed at system boot level
Supported
BIOS Drives
2
The ICP RAID BIOS supports 2 drives
7
The ICP RAID BIOS supports 7 drives
CD-ROM Boot
Disabled
Boot from CD-ROM disabled
Enabled
Boot from CD-ROM enabled
Memory Test
No test
No test at all
Standard
Standard test
Double scan
Double scan test
Intensive
Intensive test (takes longer)
Halt on
Firmware
messages
Off
Don’t stop display of firmware messages during
system boot
On
Stop display of firmware messages during system
boot when any error occurs
Immediate
Hard Disk start
Off
Initiate hard disks one at a time
On
Initiate all hard disks at the same time
Chn. SCSI-A
Termination
Auto
SCSI termination according to occupied connectors
Chn. SCSI-A
SCSI ID
0,1,2,3,4,5,6,7
Possible SCSI IDs for the channel
Chn. SCSI-B
Termination
Auto
SCSI termination according to occupied connectors
Chn. SCSI-B
SCSI ID
0,1,2,3,4,5,6,7
Possible SCSI IDs for the channel