Adaptec 2074700-R User Guide - Page 91

Remote Monitoring with the SRCD Remote Access, Service

Page 91 highlights

Installing Berkeley UNIX FreeBSD umount \ 'device path' 2. Uninstall the driver package using the command: pkg_delete iir-1.1 9.5 Remote Monitoring with the SRCD Remote Access Service srcd is the remote access service for IIR controllers. With srcd running, you can manage disk arrays from a remote workstation using storage management software (for example, StorCon) via TCP/IP. 9.5.1 9.5.1.1 9.5.1.2 SRCD Installation Instructions Install the SRCD package 1. SRCD is installed as part of the IIR package. If you have not done so already, copy file iir-11.tgz from the floppy. For example, for a DOS-formatted floppy: a. # mount -t msdos /dev/fd0 /mnt b. # cp /mnt/iir-1.1.tgz /tmp/iir-1.1.tgz c. # umount /mnt 2. Install the package with the command: # pkg_add iir-1.1.tgz This process will install the IIR driver, IIR driver source code, and modify the system configuration files, STORCON.IIRCFG and SRCD utilities, appropriately. For detailed information about on these utilities refer to their man pages. 3. Reboot server to put changes in effect. The installed package contains the iir driver for FreeBSD 4.x and will automatically start during the boot process. Configuring SRCD Upon completing the procedure in the previous section, SRCD is now installed and can be used to manage the IIR RAID subsystem. 1. Configure SRCD by invoking the following command: # /usr/sbin/srcdconf.sh 2. Remote administration/configuration of the controller on the FreeBSD machine is now possible. Software Installation and User's Guide 91

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214

Software Installation and User’s Guide
91
Installing Berkeley UNIX FreeBSD
umount \ ‘device path’
2.
Uninstall the driver package using the command:
pkg_delete iir-1.1
9.5
Remote Monitoring with the SRCD Remote Access
Service
srcd
is the remote access service for IIR controllers. With srcd running, you can manage
disk arrays from a remote workstation using storage management software (for example,
StorCon) via TCP/IP.
9.5.1
SRCD Installation Instructions
9.5.1.1
Install the SRCD package
1.
SRCD is installed as part of the IIR package.
If you have not done so already, copy
file iir-11.tgz from the floppy. For example, for a DOS-formatted floppy:
a. # mount -t msdos /dev/fd0 /mnt
b. # cp /mnt/iir-1.1.tgz /tmp/iir-1.1.tgz
c. # umount /mnt
2.
Install the package with the command:
# pkg_add iir-1.1.tgz
This process will install the IIR driver, IIR driver source code, and modify the system
configuration files, STORCON.IIRCFG and SRCD utilities, appropriately.
For
detailed information about on these utilities refer to their man pages.
3.
Reboot server to put changes in effect.
The installed package contains the iir driver for FreeBSD 4.x and will automatically start
during the boot process.
9.5.1.2
Configuring SRCD
Upon completing the procedure in the previous section, SRCD is now installed and can be
used to manage the IIR RAID subsystem.
1.
Configure SRCD by invoking the following command:
# /usr/sbin/srcdconf.sh
2.
Remote administration/configuration of the controller on the FreeBSD machine is now
possible.