Adaptec 2074700-R User Guide - Page 97

Launching ICPCON Under OpenServer, Launching ICPCON Under UnixWare, Launching ICPCON Under FreeBSD,

Page 97 highlights

ICP RAID Console When finished using ICPCON, the console log level can be set back to the default level using the following command: dmesg -n 7 This behavior is not observed if the ICPCON utility is used from an X-windows terminal window. 10.2.4 Launching ICPCON Under OpenServer To use the ICPCON program under OpenServer (2.x, 4.x and 5.x), substitute the standard terminal entry for a new one: cd /usr/lib/terminfo Enter tic src386.src Enter Before each loading of ICPCON, activate the terminal: TERM = src386 Enter export TERM Enter These two lines inserted in the .profile file are automatically processed during each login. The ICPCON program itself is copied during the OpenServer installation into the /etc directory. ICPCON is launched by entering: ICPCON Enter 10.2.5 Launching ICPCON Under UnixWare Launch ICPCON by typing the following at the prompt: ICPCON Enter 10.2.6 Launching ICPCON Under FreeBSD Launch ICPCON by typing the following at the prompt: ICPCON Enter 10.2.7 Un-installing the RAID Software Suite Warning: Uninstalling the RAID Software Suite (including the Windows device driver for the Controller) from a computer that has the operating system installed on a host drive will result in the inability to reboot the operating system. This could result in data loss. So if the boot drive is attached to the ICP RAID controller, do not remove the device driver from the system. To remove the RAID Software Suite from Windows 2000 follow the instructions below. Software Installation and User's Guide 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214

Software Installation and User’s Guide
97
ICP RAID Console
When finished using ICPCON, the console log level can be set back to the default level
using the following command:
dmesg -n 7
This behavior is not observed if the ICPCON utility is used from an X-windows terminal
window.
10.2.4
Launching ICPCON Under OpenServer
To use the ICPCON program under OpenServer (2.x, 4.x and 5.x), substitute the standard
terminal entry for a new one:
cd /usr/lib/terminfo Enter
tic src386.src Enter
Before each loading of ICPCON, activate the terminal:
TERM = src386 Enter
export TERM Enter
These two lines inserted in the
.profile
file are automatically processed during each login.
The ICPCON program itself is copied during the OpenServer installation into the
/etc
directory. ICPCON is launched by entering:
ICPCON Enter
10.2.5
Launching ICPCON Under UnixWare
Launch ICPCON by typing the following at the prompt:
ICPCON Enter
10.2.6
Launching ICPCON Under FreeBSD
Launch ICPCON by typing the following at the prompt:
ICPCON Enter
10.2.7
Un-installing the RAID Software Suite
Warning:
Uninstalling the RAID Software Suite (including the Windows device driver for the
Controller) from a computer that has the operating system installed on a host drive
will result in the inability to reboot the operating system. This could result in data
loss. So if the boot drive is attached to the ICP RAID controller, do not remove the
device driver from the system.
To remove the RAID Software Suite from Windows 2000 follow the instructions below.