Asus CUR-DLS CUR-DLS User Manual - Page 82

C. NetWare 4.XX New Installations

Page 82 highlights

5. Motherboard Driver Installation 3. Highlight Disk and CD-ROM Drivers (e.g., IDEATA). Press Enter and load an additional driver. Then press the INS key. The system always defaults to the A: path. Highlight the HAM driver and press Enter. Select Yes to save and move the driver into the operating system. Press Enter for the system to copy the files. 4. Load a separate instance of the driver for every LSI controller SCSI channel or host adapter present in the system. 5. When prompted for a slot number, accept the slot numbers displayed. Make sure to write these slot numbers down for future reference. 6. When asked to edit the STARTUP.NCF file, make sure the SYMHINW.HAM or LSI_U3NW.HAM is loaded once for each LSI controller SCSI channel present in the system. Add the statement SLOT= to each load line in the STARTUP.NCF, by specifying the slot numbers written down in step 5 above, with only one slot number per load instance. The HAM driver(s) are loaded for each LSI controller SCSI channel from the first LOAD statement to the last LOAD statement. C. NetWare 4.XX New Installations 1. Begin the file server installation according to the instructions in the file server installation chapter in the Novell NetWare Installation Manual. 2. When the NetWare installation procedure prompts you for a driver disk, insert the LSI driver for NetWare diskette into drive A: Then use the INS key to select an unlisted driver. A dialog box appears. If the driver diskette is in the A: drive, press Enter to continue. The SYMHINW.HAM or the LSI_U3NW.HAM driver appears as a selection. 3. Highlight Disk and CD-ROM Drivers (e.g., IDEATA). Press Enter and load an additional driver. Then press the INS key. The system always defaults to the A: path. Highlight the HAM driver and press Enter. Select Yes to save and move the driver into the operating system. Press Enter for the system to copy the files. 4. Load a separate instance of the driver for every LSI controller SCSI channel or host adapter present in the system. User must load twice for LSI SCSI driver with different slot number from STARTUP.NCF file as below. load SYMHINW.HAM (or LSI_U3NW.HAM) Slot=10004 load SYMHINW.HAM (or LSI_U3NW.HAM) Slot=10005 5. When prompted for a slot number, accept the slot numbers displayed. Make sure to write these slot numbers down for future reference. 6. When asked to edit the STARTUP.NCF file, make sure the SYMHINW.HAM or LSI_U3NW.HAM is loaded once for each LSI controller SCSI channel present in the system. Add the statement SLOT= to each load line in the STARTUP.NCF, by specifying the slot numbers written down in step 5 above, with only one slot number per load instance. 5. Driver Installation Novell Netware 82 ASUS CUR-DLS User's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

82
ASUS CUR-DLS User’s Manual
5. Motherboard Driver Installation
5. Driver Installation
Novell Netware
3.
Highlight Disk and CD-ROM Drivers (e.g., IDEATA). Press
Enter
and load an
additional driver. Then press the
INS
key. The system always defaults to the
A:
path. Highlight the HAM driver and press
Enter
. Select
Yes
to save and move
the driver into the operating system. Press
Enter
for the system to copy the files.
4.
Load a separate instance of the driver for every LSI controller SCSI channel or
host adapter present in the system.
5
.
When prompted for a slot number, accept the slot numbers displayed. Make
sure to write these slot numbers down for future reference.
6.
When asked to edit the STARTUP.NCF file, make sure the SYMHINW.HAM
or LSI_U3NW.HAM is loaded once for each LSI controller SCSI channel
present in the system. Add the statement SLOT=<slot number> to each load
line in the STARTUP.NCF, by specifying the slot numbers written down in
step 5 above, with only one slot number per load instance. The HAM driver(s)
are loaded for each LSI controller SCSI channel from the first LOAD state-
ment to the last LOAD statement.
C. NetWare 4.XX New Installations
1.
Begin the file server installation according to the instructions in the file server
installation chapter in the Novell NetWare Installation Manual.
2.
When the NetWare installation procedure prompts you for a driver disk, insert
the
LSI driver for NetWare
diskette into drive
A:
Then use the
INS
key to
select an unlisted driver. A dialog box appears. If the driver diskette is in the
A:
drive, press
Enter
to continue. The
SYMHINW.HAM
or the
LSI_U3NW.HAM
driver appears as a selection.
3.
Highlight Disk and CD-ROM Drivers (e.g., IDEATA). Press
Enter
and load an
additional driver. Then press the
INS
key. The system always defaults to the
A:
path. Highlight the HAM driver and press
Enter
. Select
Yes
to save and move
the driver into the operating system. Press
Enter
for the system to copy the files.
4.
Load a separate instance of the driver for every LSI controller SCSI channel or
host adapter present in the system. User must load twice for LSI SCSI driver
with different slot number from
STARTUP.NCF
file as below.
load SYMHINW.HAM (or LSI_U3NW.HAM) Slot=10004
load SYMHINW.HAM (or LSI_U3NW.HAM) Slot=10005
5.
When prompted for a slot number, accept the slot numbers displayed. Make
sure to write these slot numbers down for future reference.
6.
When asked to edit the STARTUP.NCF file, make sure the SYMHINW.HAM
or LSI_U3NW.HAM is loaded once for each LSI controller SCSI channel
present in the system. Add the statement SLOT=<slot number> to each load
line in the STARTUP.NCF, by specifying the slot numbers written down in
step 5 above, with only one slot number per load instance.