Brother International KE-436C Instruction Manual - English - Page 56

DIP SWITCH, 10-1. Panel DIP switch functions

Page 56 highlights

10. DIP SWITCH Note: When changing DIP switch, the power must be off. 10-1. Panel DIP switch functions 10. DIP SWITCH 1086Q DIP switch A Switch DIPA-1 DIPA-2 DIPA-3 DIPA-4 DIPA-5 DIPA-6 DIPA-7 DIPA-8 DIP switch B Switch DIPB-1 DIPB-2 DIPB-3 DIPB-4 DIPB-5 DIPB-6 DIPB-7 DIPB-8 All DIP switches are set to OFF at the time of shipment. Motion when set to ON Presser does not automatically lift after sewing is completed. Pedal mode is switched. See "12. Setting the presser mode" − − After sewing is completed, work clamp does not automatically rise. (only in split mode) Clamping force output is produced. (Inner clamping device available as an option) − Thread breakage detector device is activated (available as an option). Motion when set to ON Single split mode activated − Thread is not trimmed after an emergency stop. Needle cooler output is produced. (Needle cooler available as an option) When a rotating-type thread breakage detector device is used, detection precision is increased from 8 to 14. When a fiber-type thread breakage detector device is used, detection precision is increased from 5 to 10. Fiber-type thread breakage detector device is ON, and DIP switch A-8 is ON (available as an option). − − KE-436C 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

10. DIP SWITCH
50
KE-436C
10. DIP SWITCH
Note:
When changing DIP switch, the power must be off.
10-1. Panel DIP switch functions
DIP switch A
Switch
Motion when set to ON
DIPA-1
Presser does not automatically lift after sewing
is completed.
DIPA-2
Pedal mode is switched.
See “12. Setting the presser
mode”
DIPA-3
DIPA-4
DIPA-5
After sewing is completed, work clamp does not automatically rise. (only in split mode)
DIPA-6
Clamping force output is produced. (Inner clamping device available as an option)
DIPA-7
DIPA-8
Thread breakage detector device is activated (available as an option).
DIP switch B
Switch
Motion when set to ON
DIPB-1
Single split mode activated
DIPB-2
DIPB-3
Thread is not trimmed after an emergency stop.
DIPB-4
Needle cooler output is produced. (Needle cooler available as an option)
DIPB-5
When a rotating-type thread breakage detector device is used, detection precision is increased
from 8 to 14.
When a fiber-type thread breakage detector device is used, detection precision is increased
from 5 to 10.
DIPB-6
Fiber-type thread breakage detector device is ON, and DIP switch A-8 is ON (available as an
option).
DIPB-7
DIPB-8
1086Q