Canon imageFORMULA DR-2010M Workgroup Scanner User Manual - Page 89
Feeding Options
View all Canon imageFORMULA DR-2010M Workgroup Scanner manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
2 When switched to Advanced Mode, the detection method can be selected (DR-2510M only). Contents Back Previous Page Next Page Feeding Options This section describes the procedure for selecting the method for feeding documents. Under Windows 1 Click the [Others] tab → select the document feeding method in [Feeding Option]. NOTE • Details of each detection method are indicated below. [Detect by Length] This detection method is effective when scanning documents of the same size. It detects double-feeding when a document is 2.0" (50 mm) longer or 2.0" (50) mm shorter than the standard length (the length of the first document). Feeding is stopped when a double-feed is detected. [Detect by Ultrasonic] This detection method is effective when scanning documents of different sizes. It uses ultrasonic waves to detect the gap between documents when more than two sheets of paper are fed at the same time. Feeding is stopped when a double-feed is detected. • The two detection methods can be used at the same time. • When the documents overlap by less than 2.0" (50 mm) or are stuck together due to static electricity, double-feeding may not be able to be detected correctly using ultrasonic. 89